9
Slit /
縫隙
Fix the Pipe and Motor Assembly with
a) Ellipse Bolt, b) P-R Washer, c) Spring Washer, d) Hexa Nut
and e) Cotter Pin.
The Slit position of the bolt should be top and bottom.
Bend the Cotter Pin at last.
使用以下物品組裝導管與發動機組件
a)
橢圓螺栓、
b) P-R
墊圈、
c)
彈簧墊圈、
d)
六角形螺帽
e)
開口銷 。
螺栓的縫隙必須位於頂部及底部。
最後折彎開口銷。
(i)
(ii)
Cotter Pin (bend) /
開口銷
(
折彎
)
a
b
c
d
e
2
2
Connect the Fork Pipe Wire to the 2 Pin Terminal.
將分叉導管線連接至
2
針端子。
3
3
WARNING /
警告
Ensure the Pipe has been fully tighten to Motor Shaft.
(Bolt tightening torque is 800~1200 N•cm).
And, Cotter Pin must fi x into Bolt and bent.
Can cause injury if Ceiling Fan drops.
確定將導管鎖緊至發動機轉動軸。
(螺栓扭緊轉距是
800~1200 N•cm
)。
而且,開口銷必須插入螺栓孔然後折彎。
若吊扇掉落會導致受傷。
Check Point After Assemble /
組裝後的檢驗點
1. Switch Lever press the Switch.
開關杆按壓開關。
2. Ellipse Bolt, P-R Washer, Spring Washer and Hexa Nut are fi rmly tightened and the
Cotter Pin is inserted and bent for safety reason.
基於安全理由,橢圓螺栓、
P-R
墊圈、彈簧墊圈及六角形螺帽已鎖緊,而開口銷已插入並
折彎。
3. All wires are connected correctly by competent personnel.
所有電線必須由能勝任的人員正確地連接。
Check /
檢查
WARNING /
警告
Electrical wiring must be done by competent personnel.
Can cause fi re, electrical shock, Ceiling Fan drops and injuries.
電線配線工作必須由能勝任的人員進行。
這可導致火災、電擊、吊扇掉落及受傷。
Live (Brown) /
火線 (棕色)
Neutral (Blue) /
零線(藍色)
2 Pin Terminal /
2 針端子
Live (Brown) /
火線(棕色)
Neutral (Blue) /
零線(藍色)
Fork Pipe Wire /
分叉導管線