background image

BIG MAX® AND JR MAX® PROPANE TORCHES 

ASSEMBLY, TESTING, AND OPERATING INSTRUCTIONS 

 

PLEASE READ AND RETAIN THIS INFORMATION FOR FUTURE REFERENCE 

 

DO NOT OPERATE this torch unless you have been properly trained or are under the supervi-

sion of someone in its proper use. Read and understand all instructions before attempting to 

use! 

FOR YOUR SAFETY! 

 

This device is intended for outdoor use only with adequate ventilation. 

 

This torch is designed for use with a vapor-withdrawal liquid propane (LP) gas cylinder 10 

pound size and larger with an OPD valve. 

 

Eye protection, gloves, proper fire retardant clothing, and boots should be worn when oper-

ating the torch. 

 

NEVER direct torch flame toward hose or propane tank. 

 

DO NOT leave torch unattended while torch is in operation. 

 

NEVER point the torch at flammable materials you do not want to burn. 

 

DO NOT stand or prop the torch on the burner end while in operation. 

 

DO NOT use matches or a cigarette lighter to light the torch. ALWAYS use a spark lighter. 

 

Secure LP cylinders in a level, upright position during operation. DO NOT lay tank on its 

side.  

 

DO NOT lift propane tank by the valve. 

 

When not in use, the gas should be turned off at the LP gas cylinder valve. Close the flame 

adjusting valve as well. When done using torch, disconnect torch from cylinder. 

 

Have an ABC Fire Extinguisher readily accessible during the operation of the torch. 

 

DO NOT apply heat or flame to tank, hose, or torch to check for leaks, or to increase the gas 

pressure. 

 

CAUTION: In daylight, the flame is barely visible.  DO NOT place hands or body parts in 

the path of the flame while lighting or operating the torch. 

 

DO NOT use torch in areas where gasoline or other flammable vapors are stored or used. 

 

CAUTION: The torch barrel becomes very hot when in use. Do not touch barrel or allow it 

to come in contact with flammable materials until it has completely cooled down.  

 

IF YOU SMELL GAS! 

 

DO NOT operate torches or any equipment if the odor of LP gas is present. 

 

IMMEDIATELY shut off all valves and extinguish any open flames. 

 

Check all equipment for leaks using leak detection fluid or soapy water. 

 

REPAIR all leaks and test for leaks prior to lighting the torch. 

 

TROUBLE SHOOTING 

Problem #3 - The Idle Boost valve is not working. 
Possible Solutions:  
1.  If you can not get full flow out of the torch with the flame adjusting valve 

all the way open, then the integral POL safety valve (built into QCC-1 Ac-

me Tank Connector) has probably detected too much gas flow and restrict-

ed the gas flow. To reset the POL safety valve, turn the LP gas cylinder 

valve completely off (clockwise), then open the flame adjusting valve to 

release any pressure in the hose (or remove the QCC-1 Acme Tank con-

nector from the LP gas cylinder and then reinstall), close the flame adjust-

ing valve, and then reopen the LP gas cylinder valve very slowly to keep a 

lot of gas from entering the hose too quickly and tripping the POL safety 

valve again.  

2.  If the flame goes to full flow with the flame adjusting valve all the way 

open but you can’t get full flow with the Idle Boost valve handle depressed, 

then the Idle Boost valve needs to be replaced. Contact KDAR Company 

for a replacement Idle Boost valve (Model 24206). 

3.  If the flame adjusting valve just spins and spins, you might have unseated 

the valve stem from the valve by accident. To fix this, you need to loosen 

the nut under the flame adjusting valve knob with an adjustable wrench. 

Then push the flame adjusting valve knob in towards the valve body while 

turning clockwise. You should feel the threads “catch” and as you continue 

to turn, the valve will close all the way. Then retighten the nut under the 

flame adjusting valve knob (be careful not to over tighten it). If this doesn’t 

work, then the Idle Boost valve needs to be replaced. Contact KDAR Com-

pany for a replacement Idle Boost valve (Model 24206). 

 

1 Year Limited Warranty. See website for more information.

 

 

OTHER SAFETY INFORMATION 

CSA 2-94 

US Requirements for Hand-Held LP Torches for use with Fuel  

 

 

 

Supply 

ANSI Z49.1 

Safety in Welding and Cutting 

NFPA 54 

National Fuel Gas Code 

NFPA 58 

Standard for the storage and handling of liquefied petroleum gases 

 

WARNING! 

This pr oduct may expose you to a chemicals including lead, 

which is known in the State of California to cause cancer. Wash your hands 

after using this product. For more information, go to 

www.P65Warnings.ca.gov.

 

Reviews: