background image

2.3 Signal words

DANGER

• Death or serious injury is imminent.

WARNING

• Death or serious injury is possible.

CAUTION

• Moderate or minor injury is possible.

2.4 Definitions

STUDIO OPERATOR

People who provide devices to users on a commer-
cial basis. The studio operator is trained to operate 
and maintain the device. She/he is responsible for 
the proper operation of the device.

USER

A person who uses the device. 

STAFF

People who are responsible for the operation, clean-
ing and disinfection and instruction of the user on 
how to operate the devices.

QUALIFIED, TRAINED AND AUTHORIZED SER-
VICE TECHNICIAN

Qualified staff who have been trained and authorized  
by the manufacturer for assembly and repair work 
with specific device.

2.5 Transport 

WARNING

Overturning load

Danger of being crushed by heavy parts 
of the equipment. 

Wear safety shoes.

To lift the device at least two persons are needed.

2.6 Environmental regulations  

Some areas of the USA and Canada have specific 
regulations regarding disposal of waste. Please 
check the laws in your area and act in accordance 
with municipal waste regulations. Please contact 
your code enforcement officials for more information 
regarding laws governing disposal in your area.

2.7 Service

REPAIRS - SERVICE - REPLACEMENT - PARTS - 
OPERATING AND ASSEMBLY INSTRUCTIONS
If you are in need of any of the above mentioned 
products or services, you should contact:
 
Laundries unlimited of Indiana, Inc.
dba Tanning Supplies unlimited.
1504 Sadlier Circle South Drive;
Indianapolis; IN 46239, U.S.A.
1-877-307-8434 (toll free) or 317-217-1700

O p e r a t i n g   I n s t r u c t i o n s

 

|

 KBL 

 

7

Summary of Contents for vibraNano beautyShaper

Page 1: ...OPERATING INSTRUCTIONS BEAUTY SYSTEM beautyShaper vibraNano ...

Page 2: ......

Page 3: ...r nor do we guarantee the accuracy and or completeness of the information EXPORT Technical equipment and versions of the devices are in accordance with the legal prescriptions of the respective country of destination Export to the European Union of the KBL products listed in this guide or operation of the systems in these countries are not permitted KBL does not accept any manufacturers liability ...

Page 4: ... 11 3 9 Special users 11 4 Unit description 12 4 1 Designs 12 4 2 Technical features 12 4 3 Standards 12 4 4 Overview of components 13 5 Connections 14 5 1 Class I ME equipment 14 5 2 Connecting the mains voltage 14 6 Installation and start up 15 6 1 Operating modes 15 7 Training instructions 16 7 1 Basics 16 7 2 Training programs 16 7 3 Instructions for the user 16 8 Training mode 17 8 1 Controls...

Page 5: ...limited 1504 Sadlier Circle South Drive Indianapolis IN 46239 U S A Manufactured 09 2020 EXAMPLE Before opening the unit switch off the circuit breakers to disconnect it from the mains supply vibraNano 110 240V 50Hz 60Hz 100W Warning Seriennummer Serial number Mains Voltage Rated capacity KBL00512345 Typ IP20 Use in dry locations only KBL GmbH Ringstrasse 24 26 56307 Dernbach Germany Manufactured ...

Page 6: ... The manufacturer gives no guarantee of results FURTHERINSTRUCTIONS BEAUTYSHAPERSYSTEM The beautyShaper system consists of a light emit ting Tower device and the training platform vibraN ano The operating instructions of the light emitting Tower device article number 0100035998 is enc losed separately with each beautyShaper delivery as part of the overall system 2 2 Safety signs This symbol indica...

Page 7: ... with specific device 2 5 Transport WARNING Overturning load Danger of being crushed by heavy parts of the equipment Wear safety shoes To lift the device at least two persons are needed 2 6 Environmental regulations Some areas of the USA and Canada have specific regulations regarding disposal of waste Please check the laws in your area and act in accordance with municipal waste regulations Please ...

Page 8: ...amaged mains power cable Only the manufacturer or specialized companies may replace the mains power cable Initial commissioning will be carried out by the man ufacturer s own service technicians or by qualified trained and authorized service technicians The device will be handed over ready for use As studio operator it is your responsibility to observe the electrical regulations applicable at the i...

Page 9: ...arding intended use Cleaning disinfection instructions The instructions and additional information from the manufacturer must be available to the staff at their workplace Regularly test your staff s safety consciousness and awareness of the risks tak ing into account the operating instructions of the device Make sure that the cleaning disinfection intervals are complied with especially the cleanin...

Page 10: ...and terms of guarantee will become invalid 3 3 Intended use This device is designed to generate vertical high intensity vibrations intended to traverse the body whole body vibration WBV and cause involuntary muscle contractions This device is used for muscle stimulation of an adult person who is in full command of his her physical sensorial and mental faculties Moreover sufficient knowledge and exp...

Page 11: ...allowed to use the device Never use the device with dirty or wet footwear Wear dry socks or thin gym shoes for the training Any type of use that differs from the provisions under the chapter Safety notes is considered mis use 3 8 Side effects Should any side effects such as nausea dizziness drop in blood pressure or itching occur these are usually harmless They are indications of excessive trainin...

Page 12: ... vibraNano space 2000 beautyShaper vibraNano pureEnergy 5 0 Item no 9113900002 Item no 9113900003 4 2 Technical features High quality lightweight design with low vibration movement unit Patented alternating sides operating principle Tread surface operating without play and with optimum application of force Electronically stabilised movement processes pro tected against overload Large integrated an...

Page 13: ... following components Case Movement unit with standing area Acrylic plate Display Sensor button Start Stop Sensor button Program Case foot Mains power switch Mains connection Device fuse Position marker foot position O p e r a t i n g I n s t r u c t i o n s KBL 13 ...

Page 14: ...echni cians The connection to the 110 240 V mains must be protected by maximum over current protection For Canada a Class A ground fault circuit interrupter GFCI has to be used Further information can be found in chapter Technical data CONNECTION REQUIREMENTS The electrical installation must be equipped with a freely accessible all pole disconnecting device in accordance with the overvoltage categ...

Page 15: ...tore this manual so that it is always readily accessible 6 1 Operating modes After switching on the mains power switch the device is in standby mode The different operating modes are explained below STANDBY MODE The device is now in the idle state i e it is connected to the mains power supply but it is not being used The movement unit is switched off The display shows the program selection Selecti...

Page 16: ...program for muscle relaxation and effortless build up of the muscular system This program is recom mended for new users and persons as described in the Special users section Phase Duration Frequency Position 1 3 min 12 Hz 1 2 2 min 15 Hz 1 3 2 min 12 Hz 2 4 2 min 15 Hz 2 5 1 min 12 Hz 1 WELLNESS The Wellness program is used especially for the pro motion of healthy effects such as weight reduction ...

Page 17: ...uttons 8 2 Program selection The desired training program can be selected by pressing the PROGRAM sensor button Following advices are highly recommend ed for safe training with the For the first period start with light and short training sessions relax program You can gradually intensify your training when you feel getting used to the vibra tions The manufacturer recommends two to three sessions p...

Page 18: ...delayed 8 4 Changing the training positions You perform five training phases during a training session With each new phase information about the training position foot position to be assumed is shown on the display Stand on the corresponding fields of the standing area FOOT POSITION FIELDS 8 5 Screen displays during the training The phase change will be announced by an audible signal RELAX TIME 2 ...

Page 19: ...ust training position The program runs through five phases which are acoustically announced In each phase the foot position must be adjusted At each change of phase after the audible sig nal always assume the foot position shown on the display Attention Train never shifted sideways Position yourself always in the middle of the symmetry axis 0 0 Training end You will be notified about the training ...

Page 20: ... by transferring through skin contact After each training session the device must be cleaned and disinfected with a cleaning and disinfectant agent Use only EPA registered quaternary ammonium germi cidal based detergent solution follow product label for use dilution such as Lucasol One Step to clean and disinfect the device and its components For thorough cleaning and disinfection the product must...

Page 21: ...x 30 33 x 25 39 vibraNano space 2000 beautyShaper 4 842 x 30 00 x 22 52 Weight 62 lb Maximum load 285 lb 130 kg Electrical connection values Protection class IP20 Mains voltage 2 phase 2 x 110 240 V 50 60 Hz Wire cross section 3 x AWG18 Internal microfuse 1 25 A t 5 x 20 mm for Canada with ground fault circuit interrupter FI Nominal capacity 100 W Machine data Amplitudes 0 4 mm position dependent ...

Page 22: ...TIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 7 LIMITATION OF LIABILITY THE COMPANY OR DISTRIBUTOR SHALL NOT BE LIABLE WHETHER IN CONTRACT OR TORT FOR ANY LOSS OR DAMAGE INCLUDING BUT NOT LIMITED TO SPECIAL INDIRECT CONSEQUENTIAL PROPERTY ECONOMIC OR PERSONAL DAMAGES OF THE END USER OR THIRD PARTIES EVEN IF ADVISED OF THE POSSIBILITIE...

Page 23: ...______ City State _________________________________ Zip Code __________________________________ Phone ____________________________________ Model o vibraNano pureEnergy 5 0 o vibraNano space 2000 beautyShaper Serial Date of Install Installer Name and Address Remarks Office Use Only Date Received ______________ Received by __________________________________ ...

Page 24: ...O p e r a t i n g I n s t r u c t i o n s KBL 24 Remarks ...

Page 25: ...O p e r a t i n g I n s t r u c t i o n s KBL 25 Remarks ...

Page 26: ...O p e r a t i n g I n s t r u c t i o n s KBL 26 Remarks ...

Page 27: ......

Page 28: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...

Reviews: