background image

OPERATING INSTRUCTIONS

Thunder

H

ybrid

Summary of Contents for megaSun space 3000

Page 1: ...OPERATING INSTRUCTIONS Thunder Hybrid...

Page 2: ......

Page 3: ...be subject to changes Therefore we do not accept any liability for nor do we guarantee the accuracy and or completeness of the information EXPORT Technical equipment and versions of the devices are in...

Page 4: ...connection 11 Start up 13 Operating modes 13 Tanning instructions 14 Instructions for the user 14 Tanning times 15 Tanning mode 16 Starting the tanning session 16 Operation during the tanning session...

Page 5: ...l indicates that due to UV radiation hazards exist to the human health This symbol indicates that due to fall ing loads hazards exist to the human health This symbol indicates the danger of pinching W...

Page 6: ...nd elec tronic components must be disposed of as e waste Fluorescent lamps must be dropped off at authorized collection points for pollutants This helps to avoid damaging effects to the environment an...

Page 7: ...s suffering from acute sunburn Persons who are prone to freckles Persons with atypical discoloured skin areas or and with more than five atypical moles with a diameter of 5 millimetres or more and per...

Page 8: ...n The tanning device may only be installed and set up by trained and authorised personnel having received safety related instruction Arbitrary modifications or conversions of the equip ment are not pe...

Page 9: ...DE OF THE TOWER DOOR OPENED 1 Door 2 Top crown 3 Facing of unit lighting at top crown 4 Grab handle left hand side 5 Interior control panel 6 Rear wall 7 Lateral part right hand side 8 Floor plate 9 L...

Page 10: ...eter which serves to adjust the external audio signal level is accessible through a maintenance hatch on the left hand side of the tower To avoid overdrive select the level adjustment accordingly The...

Page 11: ...ooth playback starts automatically The tracks can only be selected via the user s own player The volume can be controlled via the control panel of the tanning device and also via the correspond ing op...

Page 12: ...nning session is not started within 6 minutes COMPATIBILITY OF BLUETOOTH DEVICES KBL GmbH attaches great importance to hardware compatibility Due to the large number of manufac turers KBL can not guar...

Page 13: ...these Operating Instructions in a place that allows for easy access at any time Operating modes The three different operating modes and the fan run on mode are explained below STANDBY MODE The tanning...

Page 14: ...ning is only possible by greatly exceeding the permissible tanning times It is essential to avoid this UV radiation from the sun or from UV devices can cause irreversible skin or eye damage These bio...

Page 15: ...with maintenance For tube set see table Technical data SPACE 3000 SPACE 3000 HURRICANE THUNDER HYBRID EU TANNING SCHEDULE according to UV Type III and 0 3W m2 in compliance with EN 60335 2 27 Skin ty...

Page 16: ...pped with all features Starting the tanning session During the tanning session the door must remain closed in order to ensure that the ventilation works properly Close the door and place yourself in t...

Page 17: ...If you wish to make any changes you can do so in the variable section of the control panel By pressing one of the arrow buttons above or below the changeover symbol all available functions will be di...

Page 18: ...own below is displayed aquaCool is automatically re activated as soon as a full canister has been connected Volume max on min off Body fan The body fan is auto matically controlled by ACS As soon as y...

Page 19: ...o in the head area near the Interior control panel so that the user can connect his or her own player such as MP3 play ers iPods etc Use a standard 3 5 mm jack cable to connect the jack plug to the ea...

Page 20: ...standby mode provide access to standby and service functions Simply enter the corresponding sequence of numbers on the interior control panel 1 2 3 4 5 0 9 8 7 6 Switching the decorative lighting on...

Page 21: ...ations made in all menu items Press 8 EXIT to go back to the previous menu level or to exit the service menu R E S E T ON STORE UP EXIT ENTER DOWN OFF RESET SERVICE MENU BASIC OPERATION The service me...

Page 22: ...stem will not take over the changes you made See also chapter Service Menu Timeout By pressing the STORE button you save all changes you have made in all menu items 3 By pressing 8 EXIT you go back to...

Page 23: ...ion Studio Line In Treble Studio Line In High bass Studio Line In Low bass Studio Line In AQUA aquaCool aquaCool spray time Cycle time aquaCool start test cycle aquaCool endurance test aquaCool start...

Page 24: ...menu items are immediately activated The factory set CODE 2 remains valid even if an individual CODE 2 is set Individual CODES are not reset by loading the factory settings The one time input of CODE...

Page 25: ...of the week NOTE SWITCHING CYCLES Using the setting monday sunday the switching cycle will be the same for each day of the week Week Switching cycle A B Monday Sunday A ON B ON A OFF B OFF Day Switchi...

Page 26: ...um tanning time for all timers In the easyCare operating mode the setting has been fixed to 30 minutes Factory setting 33 minutes 5min 45min ENVIRONMENT 05 05 Maximum tanning time Displays the total o...

Page 27: ...ESELECTION 02 06 Audio Specifies the start setting of the voice guidance system Factory setting on on off PRESELECTION 03 06 Voice megaVoice Not available in this system PRESELECTION 04 06 Aircon Airc...

Page 28: ...layer iPod etc Factory setting on on off AUDIO 06 22 MP3 Line In Allows for the change over between pulse code and BCD code mode with the Studio music signal pending and deactivates the external chann...

Page 29: ...aption on off Factory setting on on off AUDIO 15 22 Dynamic volume adaption Sets the treble for MP3 USB operation Factory setting 14 dB 14 14 dB AUDIO 16 22 Treble MP3 USB Sets the high bass for MP3 U...

Page 30: ...anuel 1 5 min AQUA 03 06 Cycle time Starts the aquaCool test 1 cycle AQUA 04 06 aquaCool start testcycle Start press for 2s Starts the aquaCool endurance test After having selected and stored the on s...

Page 31: ...Door contact Intervall off AROMA 04 07 Aroma cabin automatic For interval operation of the cabinet scent released the number of scent releases per hour can be set here Factory setting 3 1 6 AROMA 05 0...

Page 32: ...TIMER AROMA Starts the Aroma test 1 cycle AROMA 07 07 Aroma start testcycle Start press for 2s Not available in this system AIR CONDITIONING 01 02 Aircon air conditioning Specifies the start speed se...

Page 33: ...try repeat 00000 00000 press 0 for 2s to reset the code Enter new service code 2 and repeat the entry Save settings by pressing STORE SERVICE SERVICE CODE 02 02 service code level 2 press SET to enter...

Page 34: ...ailable in this system SERVICE 07 11 RGB Setup SERVICE 08 11 SERVICE MODE press ENTER Submenu SERVICE MODE Invoked by pressing START ENTER SUBMENU SERVICE MODE Service mode without tanning Service mod...

Page 35: ...er Performs a restart of the electronics SERVICE 11 11 Reboot Reboot press for 2s Attention All unsaved changes will be discarded Lists the latest 99 events error codes info messages Detailed informat...

Page 36: ...LED controller and the O button at the RF controller at the same time wait for the LED lamp flashing several times then move away from the two buttons The LED controller is located in the door of the...

Page 37: ...es etc that you might be wearing in order to avoid scratching the surfaces Cleaning fluid must not run into the appliance TUBES To preserve the tanning power we recommend cleaning the tubes and UV lam...

Page 38: ...hapter the required tools and aids are depicted unless the correspond ing process can be carried out by one individual per son without any further auxiliary equipment The assembly is basically carried...

Page 39: ...ones of the same type The colour filter of the tanning device lighting must be replaced whenever the tube is replaced Dismantle the acrylic panes as it is described in the section Cleaning and replaci...

Page 40: ...cent lights proceed as follows Tubes are located in the door and in the side parts to illuminate the tanning device The color filter must be changed along with the tubes at the latest DOOR SPACE 3000...

Page 41: ...and door facing again LATERAL PARTS Dismantle the acrylic pane in the respective lateral part as described in section Cleaning and replacing the acrylic panes Remove the two front tubes in the left a...

Page 42: ...th due to improper handling and care can cause skin rashes and other allergic reactions Use only aquaCool and Aroma Gel sup plied by KBL Take note of the expiry date and the infor mation regarding tra...

Page 43: ...en the Aroma tin is empty a corresponding message is displayed Unlock the retaining bracket Replace the tin Reset the Aroma counter in the service menu to 0 Reset Then the message on the interior cont...

Page 44: ...RC fault SD card check replace 15 Error no access to the SD card Update via SD card failed access er ror SD card check replace 17 Parameter storage not found please connect and restart Parameter stora...

Page 45: ...nsert an original SD card See chapter Recording to an SD card Removing the SD card 214 SD card unreadable SD card defective incompatible con tent Insert a new original SD card Acknowledge the message...

Page 46: ...alues Protective class IP 20 Mains voltage 400 V 3 N 50 Hz Wire cross section 5 x 2 5 mm2 lflex Fuses Automatic fuse K type safety cut out 3 pole 3x 25 A with residual current operated circuit breaker...

Page 47: ...th EN 60335 2 27 Tubes 52x hurricane 1906 R 180W Item no 3230076136 Equivalence key range 180 N 20 27 2 0 2 8 Dimensions in mm Height x Width x Depth 2180 10 x 1400 5 x 1405 5 closed 2180 10 x 1400 5...

Page 48: ...O p e r a t i n g I n s t r u c t i o n s megaSun space 3000 hurricane Thunder Hybrid 48 Views 1400 1498 2180 2270 1958 1400 1405 2180 2270 1963 SPACE 3000 HURRICANE THUNDER HYBRID SPACE 3000...

Page 49: ...are only valid as long as the system is operated with the original tube set 160 R 32 3 2 Ratio of the NMSC effective UV irradiance 320nm AND 320nm NMSC Non Melanom Skin Cancer Erythema effective UV ir...

Page 50: ...O p e r a t i n g I n s t r u c t i o n s megaSun space 3000 hurricane Thunder Hybrid 50 Remarks...

Page 51: ......

Page 52: ...Ringstra e 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 mail megaSun kbl de www megaSun de...

Reviews:

Related manuals for megaSun space 3000