M a n u a l e o p e r a t i v o
|
megaSun space 2000
45
INFORMATION MESSAGES
No.
Info. message
Description
Remedy
203
Fill level aquaCool canister low
The content of the aquaCool canister is suf-
ficient for another 2.5 hours of operation
with a spraying time of 6 seconds each.
Replace the empty aquaCool canister with a full one. Do
not replace aquaCool with any other liquid.
204
Connection aquaCool unit
faulty
Communication between control and mod-
ule / display has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact
your Customer Service.
205
Connection audio module
faulty
206
Connection inside display
faulty
207
aquaCool canister empty
aquaCool canister empty.
Replace the aquaCool canister with a full one.
See chapter: Refilling Aroma and aquacool.
208
Aroma supply low, please
renew
System has run out of scent.
Replace the Aroma tin.
See chapter: Refilling Aroma and aquacool.
210
Low battery charge, please
renew
Button cell (CR-2032) of the control board
discharged.
Replace the button cell (CR-2032).
212
Connection RGB module
faulty
Communication between control and bus
module has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists, contact
your Customer Service.
213
SD card missing
No SD card in the audio module.
Insert an original SD card.
See chapter: Recording to an SD card/Removing the SD
card.
214
SD card unreadable
SD card defective, incompatible content.
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter: Recording to
an SD card/Removing the SD card. If the fault persists,
contact your Customer Service.
216
Error voltage supply, please
check
Power supply to the mainboard varies
Check power supply to the mainboard.
217
No voice files on the SD card,
pleas check.
No voice files on the SD card found.
Rebuild voice folder on the SD card. If necessary replace
original SD card.
224
Check tubes and temperature
sensor in the door (delta>12)
Temperature difference to high - between
the one wire sensors.
Check tubes and thermal sensors in the door. Contact
your Customer Service.
228
Check tubes and temperature
sensor in the door (temp<30)
Minimum temperature is not reached or is
fallen below in operation mode.
Check tubes and thermal sensors in the door. Contact
your Customer Service.
229
Pleas close the door, check
exhaust air
Temperature rise of 1,5 degrees in 18
seconds.
Close door. Check exhaust air.