7
Operation and Service KBL 6800/6900
3. Service Plan
Service intervals
For a safe operation of the sunbeds, regular service works are
essential and have to be documented. Cleaning works have to
be done when necessary and do not have to be documented.
Service hours
What has to be done?
see
Every day
Check the !lling level of the condensate tank and empty it if
necessary.
100
Change or clean !lter mats
5.7
500 - 600
Change burners
For inductive apparatuses:
•
Change tubes
•
Change starters
•
Reset counter of service hours
5.4
For CPI-apparatuses (with burners) in Power-mode:
•
Change tubes
•
Reset counters (8.2.2)
•
Reset counter of service hours
Check and grease ropes of the canopy drive
5.8
Check all inner tubes and – if necessary – change them.
Climatic apparatus:
•
Clean heat exchanger
•
Check the functioning of the condensate pump
5.10
600
Replace burners of the shoulder tanner.
5.6
800
For CPI-apparatuses (with burners) in Eco-mode or for CPI-
apparatuses (without burners) in Power-mode:
•
Change tubes
•
Reset counters (8.2.2)
•
Reset counter of service hours
1000
For CPI-apparatuses (without burners) in Eco-mode with KBL
CPI-tubes in Power-mode:
•
Change tubes
•
Reset counters (8.2.2)
•
Reset counter of service hours
5.4
Replace aquaCool nozzles.
5.15
1200
For CPI-apparatuses with KBL CPI-tubes in Eco-mode
•
Change tubes
•
Reset counters (8.2.2)
•
Reset counter of working hours
3000
Replace all the ropes
5.8