Connections
Connecting the mains voltage
DANGER
Live parts
Risk of fatal injury due to electric shock
when touching live parts.
- Switch off mains voltage.
- Protect against re-connection.
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection must only
be performed by qualifi ed expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifi cations are listed in the chapter
“Technical data”.
A residual current-operated circuit breaker (RCD)
must always be used. KBL-Solarien AG recommends
the following type: KBL 3200 0770 00 (type ABB F 374
63/0.03A). Should the operation of the tanning unit
cause any interference in the power supply network,
e.g. with ripple-control systems (TRA), consult your
power supply company regarding the installation of
corresponding blocking elements (audio frequency
suppressor).
Figure 8.1
green/yellow
black or 1
brown or 2
grey or 3
blue or 4
PE L1 L2 L3
N
400V / 3N / 50Hz coupling box with fuses
and residual current operated circuit
breaker (RCD) of type ABB F 374
63/0,03A (KBL 3200077000)
mains connection
Connecting an external audio
source
When connecting an external audio source, pay
attention to the correct polarity.
Figure 8.2
R-
green
Wiring on the audio equipment’s side
yellow
white
brown
R+
L-
L+
EXTERNAL AUDIO SIGNAL 100 V (OPTIONAL
FEATURE)
A transformer (KBL item no.: 9100 0170 00) is
required for the transmission of the audio signal if a
100 V audio system is connected.
The connection must be carried out by trained service
staff.