A s s e m b l y I n s t r u c t i o n s | megaSun K9S
53
6. Connections & Initial operation
6.1 Connecting mains voltage
DANGER
Live parts
Risk of death or fatal injury due to elec-
tric shock when touching live parts.
• Switch neutral
• Secure against reconnection
• Check for neutrality
• Ground and short-circuit
• Cover or shield any adjacent live parts
or components
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection work
must only be performed by qualified expert staff.
The connection to the 400 V (or 220 V) mains must
be protected by fuses. Their specifications are listed
in the chapter “Technical data”.
CONNECTION REQUIREMENTS
The electrical installation must be equipped with a
freely accessible all-pole disconnecting device in
accordance with the overvoltage category III.
This means that for full separation each pole must
have a contact gap according to the conditions of the
overvoltage category III.
A residual current-operated circuit breaker (RCD)
with short time delay is absolutely required. KBL
recommends the following type: KBL 3200 0770 00
(type (Typ ABB F 204 A - 40//0,03 AP-R).
Should the operation of the tanning unit cause any
interference in the power supply network, e.g. with
ripple-control systems (TRA), consult your power
supply company to have corresponding blocking ele-
ments (audio frequency suppressors) installed.
STANDARD 400 V MAINS CONNECTION
Summary of Contents for mega Sun K9S
Page 1: ...ASSEMBLY INSTRUCTIONS TECHNICAL DOCUMENTATION PRODUCT LINE...
Page 2: ......
Page 20: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 20 4 6 5 REMOVE FRONT PANEL...
Page 22: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 22 4 7 3 REMOVE AQUA AROMA UNIT...
Page 30: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 30 4 10 8 REMOVE ELECTRONIC BOX...
Page 38: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 38 4 13 11 REMOVE SIDE PANELING...
Page 42: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 42 4 16 3 REMOVE FEET A A A SW17...
Page 57: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 57...
Page 58: ...A s s e m b l y I n s t r u c t i o n s megaSun K9S 58...
Page 59: ......