background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuring the ESUL8P-PC2-D* 

 

1.

Connect the DIN rail or wall-mount 
brackets as required. 

2.

Connect a 48Vdc power supply, (supplied 
separately).  

3.

If using only one power source, connect 
pin 1 to pin 5 and pin 2 to pin 6 otherwise 
the Power Fail LED will be lit.

 

4.

Install SFP modules as required. 

5.

Link external devices to the switch with 
appropriate cables. 

6.

Connect the fault alarm contact if required. 

 

 

 

 

LED 

Status 

Description 

PWR1 

 

ON 
 

Power is supplied to the unit 

 

OFF 

No power to the unit 

PWR2 

 

ON 

Power is supplied to the unit 

 

OFF 

No power to the unit 

P-Fail 

 

ON 

Power to PWR1 or PWR2 has failed 

 

OFF 

Power is functioning to both or 
none of the power inputs. 

PoE 1-8 

 

ON 

The port is supplying power to the 
powered device. 

 

OFF 

There is no powered device 
attached or the power to the device 
has failed 

 

Ethernet RJ45 Port P1 – P8 Status LED

 

Each RJ45 Ethernet port has two indicators. The yellow 
lamp indicates port speed, and the green lamp indicates 
port link state.

 

Lower

 

 

OFF 

Full duplex link 

 

FLASH Collisions are occurring 

 

ON 

Half duplex link or no connection 

Upper 

 OFF 

Effective network connection has 
been established for the port 

 FLASH Data traffic is passing through the 

port 

 ON 

No effective network connection 
has been established for the port 

 

 

Ethernet RJ45 Ports P9 & P10 Status LED

 

Each RJ45 Ethernet port has two green indicators. 
The yellow lamp indicates port speed, and the green 
lamp indicates port link state.

 

Lower 
LED

 

         
       

ON 

Power is supplied to the 
unit 

 

OFF 

Port not operating at 
1000M or no connection 

Upper 
LED 

  

ON 

Effective network 
connection has been 
established for the port 

 FLASH 

Data traffic is passing 
through the port 

 OFF 

No effective network 
connection has been 
established for the port 

Link/Active 

 

ON 

SFP port link 
established 

 

FLASH 

Active data flow 

 

OFF 

No connection to the 
network 

Need Help/Troubleshooting? 

Visit our website 

http://www.kbcnetworks.com

 or 

contact your nearest KBC office or dealer: 

APAC: 

Phone: +65 98463323 
Email: 

[email protected]

 

 
EMEA: 

Phone: +44(0)1622 618787 
Email: 

[email protected]

 

 
USA: 

Phone:

 

+1 949-297-4930  

Toll Free: +1 888-366-4276  
Email:

 

[email protected]

 

 

Quick Start Guide 

ESUL8P-PC2-D*   

 

 

 

 

 

 

 

 

 

Industrial Ethernet Switch   

 

ESUL8P-PC2-D* LED Status Indicators 

 

 

 

 

 

QSG_ESUL8P-PC2-D-Rev1112 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

www.kbcnetworks.com

 

Copyright © KBC Networks Ltd. 2011   

Reviews: