 Class A ITE 

This  is  a  Class  A  product.  In  a  domestic  environment  this  product  may  cause  radio 
interference in which case the user may be required to take adequate measures. 
 

6.3

 

 FCC 

This equipment has been tested and found to comply with the limits for a Class A digital 
device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial  environment.  This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instruction 
manual,  may  cause  harmful  Interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at this own expense. 

 

 

7

 

Instruction of Disassembly          

Instruction of Disassembly of KBC Product 

(For EU Directive 2002/95/EEC-WEEE) 

 

Tools required: 

 

No. 1 Phillips screwdriver 

 

No. 2 Phillips screwdriver 

 
Steps for disassembly: 
 

1.

 

Remove tightening screws of box cover (8 screws). 

2.

 

Remove cover plate. 

3.

 

Remove tightening screws for printed circuit board (PCB). 

4.

 

Take out all PCBs. 

 

Notice: When a product reaches the end of its life – return to KBC. 
 

 

Summary of Contents for ESUL4-FL1-M2

Page 1: ...Ethernet Switch User Manual ESUL4 FL1 M2 ESML4 FL1 S2...

Page 2: ...NS 5 2 2 1 Physical Connections 6 2 3 INSTALLATION METHOD 7 2 3 1 DIN Rail Mount 7 2 3 2 Wall mount 8 2 4 ETHERNET RJ45 CONNECTIONS 9 2 5 FIBER OPTIC CONNECTIONS 9 2 6 POWER CONNECTIONS 9 2 7 GROUNDIN...

Page 3: ...ications The units have redundant power supply terminals All copper ports are automatically configured and the plug and play design provides ease and speed of installation 1 1 1 ESUL4 FL1 The ESUL4 FL...

Page 4: ...er Optical power 20dBm MM 13dBm SM Receive sensitivity 35dBm MM 28dBm SM Wavelength 1310nm MM 1310nm SM Transmission distance 0 4km MM 0 40km SM Connector SC Transmission rate 125 Mbps Electromagnetic...

Page 5: ...ail mount 24Vdc PSU terminal block is connected to 24Vdc power lines Wall mount bracket Flat head screwdriver User manual Please contact you dealer or distributor if a part is missing or damaged 2 2 C...

Page 6: ...Copyright KBC Networks Ltd Page 6 of 17 www kbcnetworks com 2 2 1 Physical Connections Front Panel Top Panel 1 PWR1 power LED1 1 Terminal block for power input 2 100Base TX port 2 Screw hole for groun...

Page 7: ...all packaging material Attach the device to a DIN rail Attach copper and or fiber cables as required Insert the male power block attached to the supplied in line PSU to the female power socket on the...

Page 8: ...sing the 2 screws that have just been removed from the DIN rail mounting plate with a Phillips No 1 or No 2 screwdriver Position the unit on the required flat surface and secure with screws via the mo...

Page 9: ...will send at the correct rate but with a default mode of half duplex 2 5 Fiber Optic Connections The ESUL4 FL1 offers one full duplex fiber port of 100Base FX which can be single mode or multi mode T...

Page 10: ...he chassis grounding cable should be connected to the grounding screw and the other end of the cable needs to be earthed The cross section area of the chassis grounding cable should be more than 2 5mm...

Page 11: ...Data traffic is passing through the port OFF No effective network connection has been established for the port Ethernet RJ45 Port Status LED Each RJ45 Ethernet port has two indicators a yellow lamp an...

Page 12: ...e 3 1 with the switch powered on connect two RJ45 ports from the switch to two test computers and send the ping command between each computer If both the computers receive the complete command without...

Page 13: ...two ESUL4 FL1 units via their fiber ports Then attach a computer to any RJ45 port on each device and send the ping command between the connected computers If both computers get the command without pa...

Page 14: ...ernet Switch User Manual Manual ESUL4 FL1_Series_HW Rev0611B Copyright KBC Networks Ltd Page 14 of 17 www kbcnetworks com 4 System Example Figure 4 1 ESUL4 FL1 Typical System Application 5 Dimensions...

Page 15: ...l shock exposure to moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SER...

Page 16: ...ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful Interference to radio communications...

Page 17: ...30 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147...

Reviews: