2.2.2
Left Side View
Item
Connection Detail
8a
Connect to camera before powering
encoder
9b
RX- Connect to Camera RX- in 4-wire set up
9c
RX+ Connect to Camera RX+ in 4-wire set
up
9d
TX- Connect to Camera RX- in 2-wire set up
9e
TX+ Connect to Camera RX+ in 2-wire set
up
10f
Switches 1~4 OFF shown in diagram
10g
Switches 5~8 ON shown in diagram
2.2.3
RS Protocol Dip Switch Selection
2.2.3.1
RS-422 / 485
The default configuration is set for RS-422 / 485. In the diagram below, white
represents the switch. The first four dip switches OFF (in the up position) with the
last four ON will set the encoder for RS-422 or 485 protocol.
Note:
The dip switches will not determine the Baud Rate. The Baud Rate must be
configured within the GUI to match the decoder, camera and PTZ system. The
default configuration is 9600 BPS.
2.2.3.2
RS-232
The reverse dip switch positions (i.e. first four ON/down and second four OFF/up)
will change the encoder into RS-232 mode.
8. Video In BNC
9. RS Data Input
10. RS Data Selector Switch
Default Configuration: RS-485/422 (shown)
8
9
10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
O
N
O
N
a
b c d e
f