background image

 

Page 5 of 8 

Dimensions (Unit = mm) 

 

C

-L

IN

K

IP

-L

IN

K

I-M

AX

Po

C

PWR

1~4

5~8

9~12

13~16

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

1

2

3

3

10/100/1000Base-T

1~4

5~8

9~12

13~16

 

 

 

Summary of Contents for eCopper EERF8-GN3-R-RX-B

Page 1: ...of the UTP channels Plug and play design ensures ease of installation with no electrical adjustment needed LED indicators are provided to show the operational status of the unit This receiver is available in 1U rack configuration Features 8 UTP ports with PoW 3 10 100 1000M Ethernet ports 1 on the front and 2 at the rear PoW management Full switching capability Connects up to 8 EERF1 LS1 T MN B tr...

Page 2: ...visible damage which may have been caused during shipping Physical Deployment This equipment must be installed and operated in accordance with instructions found in this document Failure to comply with these instructions will invalidate the warranty Application ...

Page 3: ...anel NOTICE DISCONNECT THE AC POWER CABLE BEFORE SERVICING 10 100 1000Base T 1 2 3 4 5 6 7 8 1 2 Reset Rear Panel LED Color Status Description PWR Green On The power supply is normal IP LINK Green On 3 10 100 1000M Network link is normal U LINK Green On EoU connection is normal I MAX Green On When the total power of 4 channels more than 175W PoW1 8 Green On PoW power on ...

Page 4: ...oW 3 PoW 4 PoW 5 PoW 6 PoW 7 PoW 8 PoW Notes Please use straight through cable rather than cross over cable 8 wires transmission all 8 wires need to be connected 4 wires transmission any 2 wires of PIN 1 2 4 and 5 as any 2 wires of PIN 3 6 7 and 8 as 2 wires transmission any 1 wire of PIN 1 2 4 and 5 as any 1 wire of PIN 3 6 7 and 8 as ...

Page 5: ...Page 5 of 8 Dimensions Unit mm C L IN K IP L IN K I M A X P o C PWR 1 4 5 8 9 12 13 16 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 1 2 3 3 10 100 1000Base T 1 4 5 8 9 12 13 16 ...

Page 6: ...ion time 2mS Transmission distance 400m Ethernet Port RJ45 10 100 1000M SFP optional 1G Transmission medium Cat5e 6 Standard IEEE802 3 IEEE802 3U Ethernet delay 1mS Protection ESD IEC61000 4 2 Anti thunder protection IEC61000 4 5 level 3 Operation Environment Operating temperature 20 70 Storage temperature 40 85 Humidity No Condensing 0 90 Mechanical Dimension L W H 280mm 440mm 44mm Material Alumi...

Page 7: ...ect to the grounding terminal 5 Check that the installation is correct and power on the device to be sure it is operating normally Troubleshooting Please refer to the following information if the device does not work Confirm the installation is according to the factory installation requirements Confirm the RJ45 cable order is following the EIA TIA568A or 568B industry standards The maximum transmi...

Page 8: ...Page 8 of 8 Need Help Please visit our website www kbcnetworks com or contact your nearest KBC office or dealer ...