3)

 

Use a network cable to connect the RJ45 port to the powered device 
(transmitter) or the Ethernet switch (receiver), use a coaxial cable to 
connect the BNC port of the transmitter and the receiver, and use a 
grounding wire to connect the grounding terminal; 

4)

 

Check if the installation is correct, plug in the power adapter, and check 
if the device is operating normally. 

 

Trouble Shooting 

Please refer to the following information if the device does not work: 

 

Please confirm if the installation is done according to factory installation 
requirements; 

 

Please  confirm  if  the  RJ45  cable  order  is  in  accordance  with  the 
EIA/TIA568A or 568B industry standards; 

 

The  maximum  transmission  distance  depends  on  the  signal  source  and 
cable quality. Please do not exceed the maximum transmission distance; 

 

Please replace the failed device with a proper one to check if the device 
is damaged; If the problem still exists, please contact the dealer. 

 

Warranty Information 

KBC Networks extends the Limited Warranty to the original owner/purchaser 

of this product in according to the Warranty Policy posted in KBC Networks’ 

website at www.kbcnetworks.com. 

KBC Networks extends the following Limited Warranty to the original 
owner/purchaser of this product: if this product, or any part or portion 
thereof, shall prove upon examination by KBC Networks, to be defective in 
material or workmanship, KBC Networks will repair or replace such part or 

portion at KBC Networks’ option. The warranty period on the repaired or 

replaced part or portion of this product shall be limited to the unexpired term 
of the original warranty. The buyer shall be responsible for all shipping and 
transportation of the product to KBC Networks for any performance under this 
warranty. 

 

Conditions and Exceptions: 

a) Any accident to this product, any misuse or abuse, alternation, use in 
modified form, or any attempt to repair this product shall void this warranty. 
These conditions to the warranty include, but are not limited to, incorrect 
power connections, physical damage due to mechanical shock, exposure to 
moisture, and circuit modification; 

b) Should this product prove defective following purchase, the buyer, not the 
manufacturer, distributor, or retailer, assumes the entire cost of all servicing 
or repair, except as otherwise provided by the terms of this warranty; 

Summary of Contents for eCopper EECN1-LN1-X-MX-B

Page 1: ...e supported depending on cable distance and quality The plug and play design ensures ease of installation with no electrical adjustment needed LED indicators are provided to show the operational status of the unit The size of the transmitter is suited for fitting inside camera housings and where space is minimal Features 1 UTP port and 1 coax port 12 24VDC power input Coax data rate 50Mbps 700m ba...

Page 2: ...al Deployment This equipment must be installed and operated in accordance with instructions found in this document Failure to comply with these instructions will invalidate warranty Application LAN EECN1 LN1 T MX B EECN1 LN1 R MX B Ethernet Coaxial cable Ethernet Coax Ethernet Coax Ethernet Panel Views Top View Transmitter ...

Page 3: ...ut 2 LED indicators 3 Coaxial cable connecter 4 Ethernet RJ45 port 5 Grounding terminal RJ45 Definition LED Color Status Description PWR Green On Power supply is normal C LINK Green On EoC connection is normal Ethernet Link Act Green On Blink On Ethernet link is normal Blink Data is active ...

Page 4: ...Page 4 of 8 Pin Signal 1 TD 2 TD 3 RD 4 N A 5 N A 6 RD 7 N A 8 N A Dimensions Unit mm Equipment Installation Accessories Specifications ...

Page 5: ...ercurrent 720mA Overcurrent Protection Time 2mS Transmission Distance 700m Ethernet Port Transmission Medium Cat5e 6 Standard IEEE802 3 IEEE802 3U Ethernet Delay 1mS Protection ESD IEC61000 4 2 Anti Thunder Protection IEC61000 4 5 level 3 Operation Environment Operating Temperature 20 70 Storage Temperature 40 85 Humidity Non Condensing 0 90 Mechanical Dimension L W H 76mm 37mm 29mm Material Alumi...

Page 6: ... If any missing please contact the dealer EoC transmitter receiver x1 Wall mounting clamp x1 QSG User manual x1 Screw x2 Please follow the installation steps below 1 Attach the clamp to the wall using the 3X10mm screws 2 Press the transmitter receiver into the clamp ...

Page 7: ...ding to the Warranty Policy posted in KBC Networks website at www kbcnetworks com KBC Networks extends the following Limited Warranty to the original owner purchaser of this product if this product or any part or portion thereof shall prove upon examination by KBC Networks to be defective in material or workmanship KBC Networks will repair or replace such part or portion at KBC Networks option The...

Page 8: ...t or its fitness for any purpose and the buyer agrees that this product is sold as is and that the entire risk of the quality and performance of this product is with the buyer except as otherwise provided by the terms of this warranty e Some states jurisdictions do not allow exclusions or limitations of incidental or consequential damages or limitations on how long an implied warranty lasts so the...

Reviews: