background image

KBPB & KBCC-R SUPPLEMENTAL INFORMATION

DESCRIPTION

The Anti-Plug Reversing Module used in the KBPB and KBCC-R models has been changed

from APRM-2C to APRM-3. The General Performance Specifications of these products have

not changed. This supplement is being supplied with the KBPB and KBCC-R Installation and

Operation Manuals (Part Nos. A40210A and A40225A) until the new manuals are available.

The figures below replace the figures in the KBPB and KBCC-R Installation and Operation

Manuals. For further assistance, contact our Sales Department toll free, at 800-221-6570.

Read Safety Warning 

F

SAFETY WARNING!

This drive contains electronic Start/Stop circuits which can be

used to start and stop the drive. However, these circuits are

never to be used as safety disconnects since they are not fail-

safe. Use only the AC line for this purpose. Be sure to follow all

instructions carefully. Fire and/or electrocution can result due to

improper use of this product.

Power

Main Speed Potentiometer

Forward-Brake-Reverse Switch

CHASSIS

(EARTH)

GROUND

AC LINE INPUT

ARMATURE

-

+

A

2

A

1

L

2

L

1

T

B

3

T

B

1

P

3

P

1

P

2

S

1

S

2

S

3

S

4

HIGH

WIPER

LOW

POTENTIOMETER

MAIN SPEED

BRK

REV

FWD

S

4

S

3

S

2

S

1

P

2

P

1

P

3

T

B

1

FWD-BRK-REV SWITCH

Run-Brake and Forward-Reverse Switches

Forward-Brake-Reverse Switch with

Adjustable Forward and Preset Reverse Speed

Forward-Brake-Reverse and Run-Brake-Jog

Switches with Main Speed Potentiometer

REV

T

B

1

S

3

S

2

S

4

P

3

S

1

P

1

P

2

FWD

RUN-BRAKE SWITCH

FWD-REV SWITCH

T

B

1

S

4

S

3

S

1

S

2

P

2

P

1

P

3

BRK

REV

FWD

FWD-BRK-REV SWITCH

WIPER

HIGH

LOW

POTENTIOMETER

MAIN SPEED

BRK

JOG

RUN

REV

FWD

BRK

T

B

1

S

3

S

4

S

1

S

2

P

1

P

2

P

3

RUN-BRK-JOG SWITCH

HIGH

WIPER

LOW

POTENTIOMETER

MAIN SPEED

FWD-BRK-REV SWITCH

Forward-Brake-Reverse and Run-Brake-Jog

Switches with Main Speed Potentiometer

and Remote Jog Potentiometer

Tach-Generator Feedback Connections

50 Volts per 1000 RPM Tach-Generator

7 Volts per 1000 RPM Tach-Generator

BRK

FWD

REV

S

4

T

B

1

S

3

S

2

S

1

P

3

P

1

P

2

REMOTE JOG

POTENTIOMETER

LOW

HIGH

WIPER

POTENTIOMETER

MAIN SPEED

FWD-BRK-REV SWITCH

RUN-BRK-JOG SWITCH

BRK

JOG

RUN

(ON KBMM)

-

F

-

F

+

TACH-GENERATOR

"B" TERMINAL

+

T

B

2

-

+

(ON KBMM)

"T" TERMINAL

TACH-GENERATOR

F

+

F

-

T

B

2

(A40150) – Rev. C – 7/2006

Print Code

KB ELECTRONICS, INC.

12095 NW 39th Street, Coral Springs, FL 33065-2516 • (954) 346-4900 • FAX (954) 346-3377
Outside Florida Call Toll Free (800) 221-6570 • [email protected]
www.kbelectronics.com

Reviews: