KB Electronics 9646 Installation And Operation Instructions Download Page 1

IODF INPUT/OUTPUT MULTI-FUNCTION EXPANSION MODULE KIT (PART NO. 9646) 

INSTALLATION AND OPERATION INSTRUCTIONS 

 

 

 KB 

Electronics, 

Inc. 

 

12095 NW 39th Street, Coral Springs, FL 33065-2516 

 (954) 346-4900 

 FAX (954) 346-3377 

 

Outside Florida Call Toll Free (800) 221-6570 

 [email protected] 

 www.kbelectronics.com 

Page 1 of 4  

(A40193) – Rev. A00 – 5/7/2013

 

  SAFETY WARNING!  Please read carefully before proceeding. 

This product must be installed and serviced by a qualified technician, electrician, or electrical maintenance person familiar with its 
operation and the hazards involved. Proper installation, which includes electrical connections, fusing or other current protection, 
and grounding, can reduce the chance of electrical shocks, and fires, in this product or products used with this product, such as 
electric motors, switches, coils, solenoids, and relays. Do not use this drive in an explosion-proof application. Eye protection must 
be worn and insulated adjustment tools must be used when working with drive under power. This product is constructed of 
materials (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding, and filtering of this 
product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. 
It is the responsibility of the equipment manufacturer and individual installer to supply this Safety Warning to the ultimate end user 
of this product. (SW 8/2012) 

 

The drive contains electronic Start/Stop circuits, which can be used to start and stop the drive.  However, these circuits are never 
to be used as safety disconnects since they are not fail-safe. Use only the AC Line for this purpose. 

 

Be sure to read and follow all instructions carefully. Fire and/or electrocution can result due to improper use of this product. 

 

Items Included in this Kit

:

 IODF Input/Output Multi-Function Expansion Module, Installation and Operating Instructions, Cover for Case 

A Drives, Cover for Case B Drives, Trimpot Adjustment Tool, and Warranty Card. 
 

– THE DRIVE'S INSTALLATION AND OPERATION MANUAL MUST BE READ AND UNDERSTOOD BEFORE PROCEEDING – 

– FOR ASSISTANCE, CONTACT OUR SALES DEPARTMENT –  

 

  WARNING! HIGH VOLTAGE!  DISCONNECT AC LINE BEFORE INSTALLING THE IODF. 

 
 

1 DESCRIPTION 

The IODF is used on the KBDF Series Drives to provide 
additional input/output lines and increase the functionality 
of the standard inputs/outputs of the drive. An additional 
Multi-Function Relay is also provided. See Figure 1. 
 
 
 

2 INSTALLATION

 

The IODF easily mounts onto the drive. It is secured by 
the three clips on the drive. The two connectors on the 
IODF are used to interface with the drive. See Figure 2. 
 
 

 

 

FIGURE 2 – INSTALLING THE IODF 

MEMORY

MODULE

MEMORY

MODULE

DRIVE PRIOR TO INSTALLING THE IODF

IODF INSTALLED ONTO THE DRIVE

FIGURE 1 – IODF LAYOUT

 

Summary of Contents for 9646

Page 1: ...he responsibility of the equipment manufacturer and individual installer to supply this Safety Warning to the ultimate end user of this product SW 8 2012 The drive contains electronic Start Stop circuits which can be used to start and stop the drive However these circuits are never to be used as safety disconnects since they are not fail safe Use only the AC Line for this purpose Be sure to read a...

Page 2: ...ore using the drive Disconnect the main power before making connections to the drive or the IODF To avoid electric shock be sure to properly ground the drive Application Note To avoid erratic operation do not bundle AC Line input and motor wires with each other Also do not bundle motor wires from multiple drives in the same conduit Use shielded cables on all signal wiring over 12 30 cm The shield ...

Page 3: ... 14 13 15 17 19 18 19 Common 1 N O Normally Open COM Relay Common 2 TB3 on IODF N C Normally Closed Run Fault Target Frequency 5 03 5 04 Frequency Threshold Level 5 03 5 04 Frequency Threshold Level 5 03 5 04 I 2 t or I t Fault Load Loss See 5 05 External Fault Notes 1 Common Terminals 16 and 19 are internally wired together These terminals are also internally wired to Terminals 4 and 11 on the dr...

Page 4: ...peed output and observe the display Rotate the SCALE Trimpot counter clockwise until the drive output frequency begins to drop Then rotate the SCALE Trimpot clockwise until the display returns to the maximum output frequency Set the signal Slope and Type and adjust the Gain Offset and Response Time as desired See Section 8 4 2 1 on page 30 of the manual 4 DIAGNOSTIC LEDs The two LEDs provide indic...