Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house 

wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown.

CONNECT ELECTRICAL WIRING

INSTALL GRILLE

3

Install ceiling material to complete the ceiling construction. 

Then, cut around the fan housing.

To attach the grille assembly to the fan housing, Insert the light plug from the 

grille assembly into the wire panel. (For SEP120L2,SEPD200L2,SEPD300L2)

Pinch the grille springs on the sides of the grille assembly, and position the 

grille into the housing with the grille springs in the appropriate slots. 

Push the grille assembly towards the ceiling to secure.

UNIT

BLACK (BLK)

NIGHT

LIGHT

LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

RED

WHITE (WHT)

BLUE (BLU)

FAN 

RECEPTACLE

LIGHT

RECEPTACLE

WIRE 

PANEL

UNIT

SWITCH BOX

WHT

WHT

WHT

FAN

SWITCH

LINE

IN

GRD

GRD

BLK

BLK

WHT

LIGHT

SWITCH

NIGHT LIGHT

SWITCH

BLU

RED

LIGHT

NIGHT

LIGHT

FAN

For model SEP120

For models  SEP120L2   SEPD200L2   SEPD300L2

WIRE 

PANEL

UNIT

BLACK (BLK)

SWITCH BOX

       FAN

SWITCH

POWER SUPPLY

120V AC

GROUND (GRD)

WHITE (WHT)

FAN 

RECEPTACLE

FAN

Summary of Contents for SEPD200L2

Page 1: ...vice disconnecting means to prevent power from being switching on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d ...

Page 2: ...sition the ventilator with the bottom edge of the hanger bar tabs are flush with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Select a proper hole and secure the hanger bars together using one screw 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductw...

Page 3: ...20L2 SEPD200L2 SEPD300L2 Pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure UNIT BLACK BLK NIGHT LIGHT LIGHT SWITCH BOX FAN 120V AC LINE IN GROUND GRD RED WHITE WHT BLUE BLU FAN RECEPTACLE LIGHT RECEPTACLE WIRE PANEL UNIT SWITCH BOX WHT WHT WHT ...

Page 4: ...THER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages Some states do not allow the exclusion of incidental or consequential damages so this limitation may not apply to you Some...

Reviews: