KAZE APPLIANCES SEPD200L2 Manual Download Page 1

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.

    DO NOT MOUNT THIS PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off

    power unit.

4. Please read specification label on product for further information and requirements.

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit

with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-

ses, replace the motor with the exact service motor. The impeller should also be replaced.

See “Connect Wiring” for details. 

The fan, light, and night light can be operated separately. Use a 3-function wall control. (For models SEP120L2,

SEPD200L2,SEPD300L2) 

MODEL:

VENTILATION FAN

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to 

prevent power from being switching on accidentally. When the service disconnecting means cannot be locked, securely 

fasten a prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 

equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such 

as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected 

branch circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces 

within walls or ceilings or into attics, crawl spaces, or garages

k).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed 

Control Device.

l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

Cod: 0060301933

SEP120

SEP120L2

SEPD200L2 SEPD300L2

Summary of Contents for SEPD200L2

Page 1: ...vice disconnecting means to prevent power from being switching on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards d ...

Page 2: ...sition the ventilator with the bottom edge of the hanger bar tabs are flush with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Select a proper hole and secure the hanger bars together using one screw 3 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductw...

Page 3: ...20L2 SEPD200L2 SEPD300L2 Pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure UNIT BLACK BLK NIGHT LIGHT LIGHT SWITCH BOX FAN 120V AC LINE IN GROUND GRD RED WHITE WHT BLUE BLU FAN RECEPTACLE LIGHT RECEPTACLE WIRE PANEL UNIT SWITCH BOX WHT WHT WHT ...

Page 4: ...THER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages Some states do not allow the exclusion of incidental or consequential damages so this limitation may not apply to you Some...

Reviews: