1. Power: 

With the power knob in the OFF position ( ), plug the filled humidifier into a polarized

120V outlet. 

Do not force the polarized plug into the outlet

; It will only fit one way. To avoid 

electric shock 

do not 

plug in humidifier with wet hands.

2. Output: 

Turn Power Knob to high (

) or low ( ) to select desired humidity level. The green

light around the Power Knob will illuminate and after 1-2 minutes your humidifier will produce a 

visible steam. 

3. Humidity Level: 

A comfortable humidity level is between 40-60%.

To monitor your humidity level it is recommended you use a hygrometer such as the Vicks V70 

or V70-CAN model or the Honeywell H10C model. If condensation appears on walls or windows 

the humidity level is too high. If this occurs, open a door and turn humidifier off or down.

4.

CAUTION

Do not

 remove the Cooling Chamber, Removable Tray, Water Tank or

Medicine Cup when humidifier is in use, or for at least 20-30 min after unit has been turned off 

and unplugged. 

 CAUTION:

 Before moving humidifier, turn humidifier off, unplug and wait 20-30 min.  

Do not 

operate your humidifier without the Water Tank in place or if the unit is empty.

 Do not 

operate your humidifier without the Cooling Chamber, Removable Tray, or Medicine Cup properly 

assembled.

 Step 4

Liquid Inhalants such as Vicks VapoSteam

®

 or Kaz Inhalant can be used in the medicine cup to 

provide soothing menthol vapors to help provide comfort.. 

ONLY USE LIQUIDS THAT ARE RECOMMENDED FOR THIS TYPE OF HUMIDIFIER.
1.

Add 1 TB (tablespoon) inhalant to the Medicine Cup.

2. NOTE:

 Some residue from inhalant may be left in Medicine Cup after use. With the humidifier

turned off, unplugged and cooled for at least 20-30 min, gently wipe residue from Medicine Cup.

3. Do not 

add liquid inhalants or any additives other than those recommended by the manufacturer

and 

do not

 add liquid inhalants or any additives directly to the water. Doing so can have adverse 

effects on the humidifier.

 Step 2

 Step 1

Liquid Inhalant

 Step 3

To properly clean your humidifier we recommend the process of scale removal (descaling) 

and disinfecting shown below. Perform the descaling and disinfecting steps separately.  
NOTE: 

All Maintenance should be done in the kitchen or bathroom on a water resistant surface 

near a faucet.

Dishwasher safe: 

The following parts are 

top rack

 dishwasher safe for residential dishwashers 

operating at temperatures below 70°C/158°F. 

Cooling Chamber

Removable Tray

Mist Outlet/
Medicine Cup

Run the dishwasher on the light duty or normal cycle.  

Do not

 wash with soiled articles/dishes. 

Do not use detergents

. If you 

use your dishwasher you will 

not

 need to follow the disinfecting and scale 

removal procedure for these parts.

NOTE: Do not place parts on lower rack of dishwasher. Doing so 

could cause damage to the humidifier parts and dishwasher.

  

The Base and Water Tank are NOT dishwasher safe.

Placing these parts in the dishwasher will damage your  

humidifier and render it unable to operate properly.

Instructions for Scale Removal

1.

CAUTION:

 Always turn the Power Knob to O (Off) and disconnect the power cord from the

electrical outlet before cleaning.
If the humidifier has recently been in use, wait 20-30 min for the unit to cool before beginning 

cleaning process.
2. Remove Water Tank and empty.
3. Disassemble the Cooling Chamber by gently pushing on the Locking Tab and pulling Cooling

Chamber upwards.
4. Remove Removable Tray by pushing on the Locking Tab and gently pulling Removable

Tray upwards.

 Step 3

 Step 2

 Step 1

 Step 4

Summary of Contents for HWM705 series

Page 1: ...contact a qualified electrician Do not attempt to defeat this safety feature 5 To avoid fire or shock hazard plug the appliance directly into a 120V AC electrical outlet 6 The appliance should always be unplugged and emptied when not in operation or while being cleaned Shut off and unplug humidifier before moving Do not move or tilt humidifier while it is in operation Plug and unplug unit with dry...

Page 2: ...U S or Vicks VapoSteam VS177CANEA in Canada Can be added to medicine cup area to provide soothing menthol vapors to help provide comfort Protec Cleaning Cartridge PC 1BXN in U S or PC 1C in Canada Keeps your humidifier cleaner longer Continuously cleans and protects humidifiers against bacteria and mold for 30 days 1 Remove humidifier and all contents from box Save Use and Care Manual for future u...

Page 3: ...e humidifier turned off unplugged and cooled for at least 20 30 min gently wipe residue from Medicine Cup 3 Do not add liquid inhalants or any additives other than those recommended by the manufacturer and do not add liquid inhalants or any additives directly to the water Doing so can have adverse effects on the humidifier Step 2 Step 1 Liquid Inhalant Step 3 To properly clean your humidifier we r...

Page 4: ...Cap is not tight Mist intensity is set too high for room size or pre existing humidity level NOTE Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit Customer failure to follow these instructions may void the warranty Instructions for Scale Removal continued 5 Fill Heating Chamber with 1 cup undiluted whi...

Reviews: