2.2 Location requirements
2.1.2 How to transport
Enough space for installation and maintenance shall be
preserved.
The base surface should be flat, surface should be inclined no
more than 2° and able to bear the weight of the unit and
suitable for installing the unit without increasing noise or
vibration.
No flammable gas is leaked nearby.
Recommending install the main uint at indoor ambient range of
5~43
ć
.
It is not allow to install the unit at outdoor or rain
achieving place. The ambient temperature around the indoor
unit must be
≥
5
ć
to prevent water form freezing.
1)
1)
2)
2)
3)
4)
Prevent water from
flowing backwards
2.1 Unpacking
2.1.1 Accessories
2. BEFORE INSTALLATION
1
Accessory Name
Qty. Shape
Purpose
Owner’s & Installation
Manual
Installation and use instruction
This manual
1
One Way Valve
Introduction of technical
parameters
Connect the inlet and outlet
water pipes
Fixed water tank
Technical Parameter
Table
Water Pipe Joint
Fixed Strip
1
2
1
In order to avoid scratch or deformation
of the unit surface, apply guard boards
to the contacting surface.
No contact of fingers and other things
with the vanes.
Don’t incline the unit more than 15°
in moving, and keep it vertical when
installing.
This unit is heavy, it need to be carried by two or more persons,
othewise might cause injury and damage.
>75°
Gradient limit>75°
CAUTION
The earthing pole of socket must be
grounded well, make sure that power
supply socket and plug are dry enough and
connected tightly.
How to check the power supply socket and
plug are qualified?
Turn on power supply and keep the unit
running for a half hour, then turn off power
supply and plug out, check
whether the socket and plug is hot or not.
Before cleaning, be sure to stop the opera
tion and turn the breaker off or pull out the
power plug.Otherwise, an electric shock
and injury may be caused.
Water temperature over 50
℃
can cause severe burns
instantly from
scalds. Children, disabled
and elderly are at highest
risk of being scalded. Feel
water before bathing or
showering.
Water temperature limiting
valves are recommanded.
Do not operate the unit with a wet hand.
An electric shock may be caused.
The installation height of power supply
should be over 1.8m, if there is any water
spattered, separate the power supply from
water.
A one-way valve must be installed on the
water inlet side, which is available from
accessories, see manual "accessories" part.
It’s normal if some water drops from the
hole of PT valve during operation. But, if
there is a great amount of water, call your
service agent for instructions.
After a long term use, check the unit base
and fittings.
If damaged, the unit may sink and result in
injury.
Arrange the drain pipe to ensure smooth
draining.
Improper drainage work may cause wetting
of the building, furniture etc.
Do not touch the inner parts of the
controller.
Do not remove the front panel. Some parts
inside are dangerous to touch, otherwise a
machine malfunction may be caused.
Do not turn off the power supply.
System will stop or restart heating auto
matically. A continuous power supply for
water heating is necessary, except service
and maintenance.
If the unit has not been used for a long
period of time (2 weeks or more),
hydrogen gas will be produced in the water
piping system.
Hydrogen gas is extremely flammable. To
reduce the risk of injury under these condi
tions, it is recommended that open the hot
water tap for several minutes at the kitchen
sink before using any electrical appliance
connected to the hot water system. When
hydrogen is present, there will probably be
an unusual sound such as air escaping
through the pipe as the water begins to
flow. There should be no smoking or open
flame near the tap at the time it is open.