background image

4

6.   OPERATION PRECAUTIONS

Read this operation manual carefully before operating the unit. Grasp 

the key points in the manual, and seek help from the con distributor 

for any question.
This air conditioner is designed to provide a comfortable room 

environment, and is applicable to the purposes described in the 

manual only.

     

Inspection before operation

    Check whether the ground wire is broken or disconnected.

    Check whether the air filter is installed properly.

     If the air conditioner has been out of service for a long period, 

be sure to clean the filter before resuming the service of the air 

conditioner. Cleanse it biweekly during continuous service of the 

air conditioner. For details, see the chapter headed “Maintenance 

and Upkeep”.

     Check that the air inlet and outlet of the indoor/outdoor unit are not 

blocked.

   

Safety precautions

     Do not let the indoor unit or remote controller moistened. 

Otherwise, electric short-circuit or fire may occur.

     Do not use or store flammable gases or liquids near the air 

conditioner, e.g., hair styling jelly, paint and gasoline. Otherwise, 

fire may occur.

     Do not touch the deflector plate while the air deflector works. 

Otherwise, the fingers may be clipped or the driving parts of the 

indoor unit deflector may be damaged.

     When the fuse blows out, do not substitute any fuse of an improper 

nominal current value or other wires. Substituting conductor or 

copper wire for fuse may cause damage to the air conditioner or 

cause fire.

     Do not insert any objects like sticks into the air inlet or outlet. It is 

very dangerous when the blade touches any foreign objects during 

high-speed running of the fan.

     Do not remove the fan cover of the outdoor unit. The fan without 

any external cover is very dangerous during high-speed running.

     Do not use the main power switch to start up or shut down the air 

conditioner, but use the ON/OFF button on the remote controller.

     Do not let children toy with the air conditioner.

     Do not repair the air conditioner by yourself. Delegate professional 

maintainers to do the repair.

     Cut off the main power switch before cleansing the filter and the 

unit body. This unit is grounded and provides dual protection 

against accidental electric shock. No electric shock will occur when 

you normally replace or cleanse the filter or use a dry cloth to clean 

the unit body. However, to be on the safe side, cut off the power 

supply before performing maintenance or up-keep work.

     The electric circult must be installed RCCB and manual switch

Table 6-1

Cooling 

operation

Outdoor temperature: -15~43°C
Intdoor temperature: 17~32°C

Heating 

operation

Outdoor temperature:-15~24°C
Intdoor temperature: 10~30°C

Dewetting 

operation

Outdoor temperature: 17~43°C
Intdoor temperature: 17~32°C

7.   BEAT OPERATION

     Pay attention to the following issues to ensure that the system is 

in normal operation. For detailed operation procedure, see the 

corresponding instructions.

     Adjust the air flow direction properly, and do not aim the air flow at 

the persons in the room directly.

     Adjust the room temperature properly to get a comfortable 

environment. Avoid being too hot or too cold.

     In the cooling operation, use curtains or window shades to prevent 

direct sunlight.

     Close all windows and doors. If the doors and windows are open, 

the air in the room will flow out and the effect of cooling/heating 

will be compromised.

     Set the predetermined operation time through the remote 

controller.

     Do not put any objects near the air inlet or outlet which obstruct 

air flow. Otherwise, it will reduce efficiency of the air conditioner or 

even lead to system interruption.

NOTE

     

The indoor relative humidity should be lower than 80%. If 

the air conditioner works in an environment with a relative 

humidity higher than mentioned above, the surface of the air 

conditioner may condensate.In this case, it is recommended 

to set the air speed of the indoor unit to high.

          

If the air conditioner works in other than the above 

circumstances, functions may fail.

NOTE

     

Before leaving the unit idle for a long period, cut off the 

main power switch, and remove the batteries in the remote 

controller. When the main power switch is turned on, a 

certain extent of electric power is consumed even if the air 

conditioner does not run. Turning off the main power switch 

can save energy. Before restart the unit, please connect the 

power supply advance 12 hours before restart the unit, for 

ensure the power the unit could proform in normally.

     

Cleanse the air filter every another two weeks. The effect 

of cooling or heating will be compromised if the air filter is 

blocked.

     

Please consign professional personnel to check, clean and 

maintain the duct, drain system regularly.

Summary of Contents for KPDH-224F DN10

Page 1: ... DN10 KPDH 280F DN10 Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference High Capacity Sets OWNER S MANUAL ...

Page 2: ......

Page 3: ... or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the unit may break down Never put any objects into the air inlet or outlet Objects touching the fan at high speed...

Page 4: ...rience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Contact you local government for information regarding the collection systems available If electrical appliances are dispos...

Page 5: ...ning in 24h or shorter time This is to warm the crankcase heat box to avoid compulsive start of condenser Pay attention not to block the air inlet and outlet Blocks may decrease the efficiency of the unit or startup the protector which will stop running NOTE Do not cut off the ground wire of the main power switch in any circumstance Do not use damaged power wires Change the damaged power wires onc...

Page 6: ...r when you normally replace or cleanse the filter or use a dry cloth to clean the unit body However to be on the safe side cut off the power supply before performing maintenance or up keep work The electric circult must be installed RCCB and manual switch Table 6 1 Cooling operation Outdoor temperature 15 43 C Intdoor temperature 17 32 C Heating operation Outdoor temperature 15 24 C Intdoor temper...

Page 7: ...tioner through the ON OFF button of the remote controller and then cut off the power supply 8 4 Startup After A Long Period Out Of Service Check the following issues Check whether the air inlet or outlet of the indoor unit and outdoor unit is blocked Remove foreign substance if any Check whether the ground wire is connected properly Check whether the condensate water is discharged normally Cooling...

Page 8: ...n the temperature changes Dust is blown out of the indoor unit When the air conditioner resumes service after a long period out of service the dust in the indoor unit will be blown out The indoor gives out smell The indoor unit absorbs the smell of the room furniture or smoking and gives it out when running Shift from cooling mode to air supply mode In order to prevent frosting of the indoor heat ...

Page 9: ...perly The refrigerant is leaked or the replenishment is deficient Detect leak and fill the refrigerantof a correct quantity Table 12 1 The shift function cannot be set Symptom Check item cause Check whether the mode marked on the screen is AUTO When you select the AUTO mode the indoor unit will select AUTO for the air speed automatically The wind speed cannot be shifted Check whether the mode mark...

Page 10: ...hut down The buttons of the remote controller do not work Check the screen of the remote controller Lock buttons 13 REPAIR In case your air conditioner fails to operate normally shut down the unit and cut off the power supply promptly Then contact the manfacturer distributor Report the model operation environment and fault information of the air conditioner in detail request for sending technician...

Page 11: ......

Page 12: ......

Reviews: