Troubleshooting Tips

When troubles occur, please check the following points before contacting a repair company.

Problem

Possible Causes

Solution

The unit is not 
working

Power failure

Wait for the power to be restored

The power is switch off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are dead

Replace the remote-control batteries

The Unit's 3-minute protection has been 
activated

Wait three minutes after restarting the unit

Poor Cooling 
Performance

Temperature setting may be higher than 
ambient room temperature

Lower the temperature setting

The heat exchanger on the indoor or outdoor 
unit is dirty

Clean the affected heat exchanger

The air filter is dirty

Remove the filter and clean it according to 
instructions

The air inlet or outlet of either unit is blocked

Turn the unit off, remove the obstruction and turn 
it back on

Doors and windows are open

Make sure that all doors and windows are closed 
while operating the unit

Excessive heat is generated by sunlight

Close windows and curtains during periods of 
high heat or bright sunshine

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off 
refrigerant

The unit starts and 
stops frequently

There's too much or too little refrigerant in 
the system

Check for leaks and recharge the system with 
refrigerant

There is air, incompressible gas or foreign 
material in the refrigeration system

Evacuate and recharge the system with refrigerant

System circuit is blocked

Determine which circuit is blocked and replace the 
malfunctioning piece of equipment.

The compressor is broken

Replace the compressor

The voltage is too high or too low

Install a manostat to regulate the voltage

Poor heating 
performance

The outdoor temperature is lower than 7ºC 
(44.5ºF)

Check for leaks and recharge the system with 
refrigerant

Cold air is entering through doors and 
windows

Make sure that all doors and windows are closed 
during use

Low refrigerant due to leak or long-term use

Check for leaks, re-seal if necessary and top off 
refrigerant

Summary of Contents for KPC-52 DR12

Page 1: ...ase check tha applicable models F GAS and manufacturer information from the Owner s Manual Product Fiche in the packaging of the outdoor unit European products only If used as MULTI unit please refer...

Page 2: ......

Page 3: ...g Tips c Error Codes 5 European Disposal Guidelines 15 Caution Risk of fire flammable materials WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and r...

Page 4: ...rate the defrosting process to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an...

Page 5: ...eating devices thoroughly ventilate the room to avoid oxygen deficiency Do not climb onto or place objects on top of the outdoor unit Do not operate the air conditioner when using fumigant insecticide...

Page 6: ...emperatures for safe and effective operation If the air conditioner is used under different conditions it may malfucntion or become less efficient COOL Mode HEAT Mode DRY Mode Indoor Temperature 17 C...

Page 7: ...losed to keep cool or warm air in the room DO NOT place objects near the air inlet and outlet of the unit This will reduce the efficiency of the unit Set a timer and use the built in SLEEP ECONOMY mod...

Page 8: ...iver Timer indicator Alarm indicator PRE DEF pre heating defrost indicator Fig 2 7 Func button LED display Operation indicator Infrared receiver Timer indicator Alarm indicator PRE DEF pre heating def...

Page 9: ...ng water Doing so creates an electrical hazard Do not use water hotter than 40 C 104 F to clean the front panel This can cause the panel to become deformed or discolored Clean the unit using a damp li...

Page 10: ...event of a refrigerant leak the LCD screen will display EC and the LED indicator light will flash Preparation For Periods Of Non Use Maintenance after Extended Non Use 1 Remove any obstacles blocking...

Page 11: ...he unit changes from COOL mode to FAN mode The unit changes its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature...

Page 12: ...h will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odour The unit may absorb odours from the environment suc...

Page 13: ...nd windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long ter...

Page 14: ...on malfunction 9 OFF E8 9 Other twin model malfunction 10 OFF E9 10 Overload protection 1 ON F0 11 Outdoor temperature sensor error 2 ON F1 12 Outdoor condenser pipe sensor error 3 ON F2 13 Discharge...

Page 15: ...n disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take ba...

Page 16: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details QSBPDLU 050AEN R32 E 1612500000328 20170905...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: