Kaysun KMF-80 DVN3 Owner'S Manual Download Page 4

owner's manual

 

2

 

 

 

 

 

 

 

 

 

 

Do not touch the heat exchanger fins.

 

These fins are sharp and could result in cutting injuries.

 

 

Do not place items which might be damaged by moisture 
under the indoor unit.

 

Condensation may form if the humidity is above 80%, the 
drain outlet is blocked, or the filter is polluted.

 

 

After a long use, check the unit stand and fitting for 
damage.

 

If damaged, the unit may fall and result in injury.

 

2.   PARTS NAMES

 

 

The  air  conditioner  consists  of  the  indoor  unit,  the 
outdoor  unit,  the  connecting  pipe  and  the  remote 
controller.  

(see Fig.1)

 

 

Force Cooling Control

 

Force cooling

 

control Button sw1                      Display control button sw2

 

 

To avoid oxygen deficiency, ventilate the room 
sufficiently if equipment with burner is used together 
with the air conditioner.

 

 

Arrange the drain hose to ensure smooth drainage. 

Incomplete drainage may cause wetting of the building, 
furniture etc.

 

 

Never touch the internal parts of the controller.

 

 

 

 

 

 

 

 

 

Force Cooling Control

 

 

sw1

 

 

sw2

 

MAIN BOARD 

(OUTDOOR UNIT)

 

 

 

 

 

 

 

 

Fig.2-1 

 

Do not remove the front panel. Some parts inside are 
dangerous to touch, and a machine trouble may happen.

 

 

Never expose little children, plants or animals directly to 
the air flow.

 

Adverse influence on little children, animals and plants may 
result.

 

Force  cooling  control  of  outdoor  unit  be  pressed  once  that  a order 
to  force  cooling  in  indoor  unit.  When  the  frequency of  outdoor  unit 
change  to  44Hz  and  then  running  it;  indoor  fan  run  in  high  speed. 
Press  the  button  again  will  exit  the  Force  Cooling  Control.

 

 

Display function

 

Th e  f u n c t i o n  o f  t e x t  r u n  c i r c u l a t es  a s  f o l l o w i n g

(1 2 / 1 4 / 1 6 K W

.

 

 

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

 

Falling or tumbling may result in injury.

 

 

Do not operate the air conditioner when using a room 
fumigation - type insecticide.

 

Failure to observe could cause the chemicals to become 
deposited in the unit, which could endanger the health of 
those who are hypersensitive to chemicals.

 

 

Do not place appliances which produce open fire in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It may cause incomplete combustion or deformation of the unit 
due to the heat.

 

 

Do not install the air conditioner at any place where 
flammable gas may leak out.

 

If the gas leaks out and stays around the air conditioner, a fire 
may break out.

 

 

The appliance is not intended for use by young children 
or infirm persons without supervision.

 

 

Young children should be supervised to ensure that they 
do not play with the appliance

.

 

 

When capacity of indoor unit greater than the sum of

 

100%, capacity of indoor unit will be attenuated.

 

 

When capacity of indoor unit greater than or equal to the 
sum of 120%, in order to ensure the effectiveness of 
machine, and then try to open the indoor units at 
different time.

 

 

The outdoor unit window-shades should be periodic 
cleaning in case of being jammed.

 

This window-shapes is heat dissipation outlet of components, if being 
jammed will cause the components to shorten their service life spans 
because of overheated for a long time.

 

 

The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper 
tube.

 

 

Normal display

 

 

Operating mode

 

(0—Standby; 2—Cooling;

 

3—Heating; 4—Forced 

cooling

 

 

Operating fan speed grade

 

(0—Power off)

 

 

The total capacity

 

requirements of the 
interior unit

 

 

The capacity requirements

 

of the revised external unit

 

 

T3 piping temperature

 

 

T4 environment temperature

 

 

T5 discharge temperature

 

(actual) (if it is over one 
hundred, it will be only 
display the hundreds

 

place and the tens place)

 

 

 

Display “--”

 

 

The last fault or protection 
code (if there is no fault or 
protection code it will be 
display “nn”)

 

 

The quantities of the operating 
interior units

 

 

Total quantities of the interior 
units

 

 

T2 average temperature 

Actual voltage AD value 

Actual current value 

PMV opening

 

The surface temperature of

 

the cooling fin

 

Summary of Contents for KMF-80 DVN3

Page 1: ...N3 KMF 120 DVN2 KMF 140 DVN2 KMF 160 DVN2 KMF 120 DTN2 KMF 140 DTN2 KMF 160 DTN2 KMF 180 DTN2 Original instructions Thank you very much for purchasing our air conditioner Before using your air conditi...

Page 2: ...ing connection part connection part in side NOTE All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model...

Page 3: ...s into the air inlet or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquerer paint near the unit It may cause a fire Never touch...

Page 4: ...to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open fire in places exposed to the air flow from the...

Page 5: ...let Blocks may decrease the efficiency of the unit or startup the protector which will stop running 4 2 About power cut If power is cut during operation stop all the operation immediately Power comes...

Page 6: ...heat wind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and the...

Page 7: ...Input current protection Compressor discharge protection temperature Condenser high temperature protection Inverter module protection Typhoon protection Indoor evaporator hi temp protection Module mal...

Page 8: ...is because dust has gotten into the unit Symptom 6 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 7 The outdoor unit fan...

Page 9: ...is blocked Outdoor unit and indoor unit heat exchanger are dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shines Too much h...

Page 10: ...the MODE indicated on the display is FAN ONLY The temperature cannot be set during FAN mode The indication on the display disappears after a lapse of time Check whether the timer operation has come t...

Page 11: ...MD14U 025BW 202000172622...