⑦
CONFIRM / UNLOCK
If the screen and buttons are unlocked, press this button to load the setting parameters after setting
a parameter:
If it is pressed within 10 sec, the setting parameters will be loaded into the unit;
If it is pressed after 10 sec, it resets all the parameters.
If the screen and buttons are locked, press and hold this button for 3 s to unlock them.
⑧
- / DOWN
Decreases the corresponding value.
Pressed for more than 1s: the value decreases continuously
⑨
ON/OFF button and LED indicator
Unità in standby: press
, the unit turns off.
Unità on: press
, the unit turns off.
Unit off: press
, the unit turns on.
LED: on: unit on; off: unit off.
+
Choose 01
Press the confirmation button.
the DISINFECT icon and the first two values of 8888 flashthe
hour can be changed.
Press the confirmation button,
the last two values of 8888 flashthe
minutes can be changed.
After setting, press OK to save the settings and exit.
Press the Cancel button to exit the disinfection time setting.
If no disinfection start time has been set, disinfect once every 7 days using 23:00 as the
default setting.
If the disinfection start time has been set, disinfection will be carried out once every 7 days
according to the disinfection start time set.
Anti-legionella
+
Choose 02
Press the confirmation button.
the LCD displays F or C; press
to switch from °F to °C and vice versa
Changing the unit of measurement °F / °C
+
Choose 03
Press the confirmation button.
the alarm beeps briefly
the error code / protection is reset
Alarms reset