owner’s manual

 

4

 

 

Maintenance before a long stop period

 

(eg. at the beginning of the cold season)

 

 

 

Drain the water system(for all heat exchangers).

 

 

To avoid the risk of rupture due to freezing, it is advisable to 
drain the water from the system at the beginning of the cold 
season

 

Maintenance before a long stop period

 

(eg. at the end of the season)

 

 

 

Let the indoor units run in fan only operation for about half a 
day in order to dry the interior of the units.

 

 

Clean  air  filters  and  casings  of  indoor  units.  Refer  to  " 
Cleaning  the  air  filter"  for  details  on  how  to  proceed  and 
make  sure  to  install  cleaned  air  filters  back  in  the  same 
position.

 

 

 
 

S faceplate

 

 
 
 
 
 
 
 
 
 
 
 

 

air filter

 

 
 

 net of clear air 

 

mesh enclosure of clear air

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig.6-1

 

 

Cleaning the air filter and net of clear air

 

 

 

The  air  filter  can  prevent  the  dust  or  other  particulate  from 
going  inside.  In  case  of  blockage  of  the  filter  ,  the  working 
efficiency of the air conditioner may greatly decrease .

 

Therefore, the filter must be cleaned once two weeks during 
long time usage.

 

 

If the air conditioner is installed in a dust place, clean the the 
air filter frequent.

 

 

If  the  accumulated  dust  is  too  heavy  to  be  cleaned,  please 
replace  the  filter  with  a  new  one(replaceable  air  filter  is  an 
optional fitting).

 

 

Open the faceplate, then Dismantle the air filter and net of 
clear air.

 

Clean the air filter

 

Vacuum cleaner or pure water may be used to clean the air 
filter.If the dust accumulation is too heavy , please use soft 
brush and mild detergent to clean it and dry out in cool place

 

The air-in side should face up when using vacuum cleaner.

 

(Refer to Fig 6-2)

 

The air-in side should face down when using water.

 

(Refer to Fig 6-3)

 

 

Re-install the air filter and net of clear air.

 

Close the faceplate

#

$

!

!

CAUTION

 

Do not dry out the air filter under direct sunshine or with fire.

 

 

 

 

C faceplate

 

 
 
 
 
 
 
 
 

Fig.6-2

 

 
 
 
 
 
 
 
 
 
 
 

 

Fig.6-3

 

7.  FOLLOWING SYMPTOMS ARE NOT AIR 

CONDITIONER TROUBLES

 

 

Symptom 1: The system does not operate

 

The air conditioner does not start immediately after the ON/OFF 
button on the remote controller is pressed.

 

If  the  operation  lamp  lights,  the  system  is  in  normal  condition. 
To  prevent  overloading  of  the  compressor  motor,  the  air 
conditioner starts 3 minutes after it is turned ON.

 

 

If  the  operation  lamp  and  the  "PRE-DEF  indicator(cooling  and 
heating  type)  or  fan  only  indicator(cooling  only  type)"  light,  it 
means you choose the heating model, When just starting, if the 
compressor  has  not  started,  the  indoor  unit  appears  "anti-cold 
wind" protection because of its overflow outlet temperature.

 

 

 
 
 

 

air filter

 

 
 

 net of clear air 

 

mesh enclosure of clear air

 

Symptom 2: Change into the fan mode during cooling 

mode

 

In  order  to  prevent  the  indoor  evaporator  frosting,  the  system 
will  change  into  fan  mode  automatically,  restore  to  the  cooling 
mode after soon.

 

 

When  the  room  temperature  drops  to  the  set  temperature,  the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode.

 

Summary of Contents for KFC-AY-2T-250D3

Page 1: ...2T 400D1 KFC AY 2T 600D1 KFC AY 2T 250D2 KFC AY 2T 400D2 KFC AY 2T 600D2 KFC AY 2T 250D3 KFC AY 2T 400D3 KFC AY 2T 600D3 Thank you very much for purchasing our air conditioner Before using your air c...

Page 2: ...let Air outlet Infrared signal Temperature receiver display Operation lamp Timer indicator Display panel S E T T E M P E R A T U R E C A U T O C O O L D R Y H E A T F A N H I G H M E D L O W T E M P F...

Page 3: ...for special treatment is necessary To prevent water leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the water if by any chanc...

Page 4: ...onditioner will run under AUTO mode The remote controller operation is enabled to operate according to the received signal 2 FORCED COOL The OPERATION lamp flashes the air conditioner will turn to AUT...

Page 5: ...duce cooling or heating efficiency please clean it once two weeks S faceplate 6 MAINTENANCE Vertical air deflector Vertical air deflector Fig 5 2 5 ADJUSTINGAIRFLOWDIRECTION While the unit is in opera...

Page 6: ...air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner Refer to Fig 6...

Page 7: ...DC motor malfunction E3 T2 evaporator sensor malfunction E2 T1 evaporator sensor malfunction E8 Water level alarm malfunction E7 EEPROM communication error 8 TROUBLESHOOTING 8 1 Troubles and causes o...

Page 8: ...ng FAN mode The indication on the display Check whether the timer The air conditioner operation will disappears after a lapse of operation has come to an stop up to the set time time end when the TIME...