To avoid electric shocks or fires, install an earth leak 
detector.

 

 

Ensure the unit is grounded.

 

To avoid electric shocks, ensure the unit is grounded and that 
the earth wire is not connected to a gas or water pipe, lightning 
conductor, or telephone earth wire.

 

 

To avoid injury, do not remove the fan guard on the 
outdoor unit.

 

 

Do not use the unit if your hands are wet.

 

Doing so puts you at risk of an electric shock.

 

 

Do not touch the heat exchanger fins.

 

These fins are sharp and you could cut you.

 

 

Do not place items which might be damaged by moisture 
under the indoor unit.

 

Condensation may form if the humidity is above 80 percent, if 
the drain outlet is blocked or if the filter is polluted.

 

 

Check the unit stand and fitting for damage after the unit 
has been running for a long time.

 

If the stand is damaged, the unit may fall and cause an injury.

 

2.

 

PART NAMES

 

■ 

Four-way cassette type

 

Air Out Louver (Adjustable)

 

For the detailed information about the

 

Two-direction or Three-direction Air Outlet, 
please consult your local dealer.

 

 

Grounding Screw 
(In the control box)

 

 
 

 

Lock buckle

 

(For closing the Air Grille)

 

 

Air Intake

 

(Intake air from here)

 

 

 

Air Filter

 

(Filter the dust in the intake air)

 

 

To  avoid  oxygen  deficiency,  ventilate  the  room 
sufficiently if equipment with a burner is used at the same 
time as the air conditioner.

 

 

Arrange the drainage hose to ensure smooth drainage.

 

Incomplete drainage may cause water leaks.

 

 

Do not touch the internal parts of the controller.

 

Do not remove the front panel. Some internal parts may cause 
injury or be damaged.

 

 

Never expose little children, plants or animals directly to 
the air flow.

 

Never  expose  children,  plants  or  animals  directly  to  the  air    
flow.

 

 

Do  not  allow  a  child  to  mount  on  the  outdoor  unit  and     
don’t place objects on it to avoid injury.

 

Falling or tumbling may result in injury.

 

 

Do  not  run  the  air  conditioner  when  fumigating  a  room   
with  insecticide  as  chemicals  could  get  in  the  unit, 
causing respiratory problems for people affected.

 

Failure  to  observe  could  cause  the  chemicals  to  become 
deposited  in  the  unit,  which  could  endanger  the  health  of        
those who are hypersensitive to chemicals.

 

 

Do not place appliances that produce open fire in places 
in  the  path  of  the  air  flow  from  the  unit  or  under  the           
indoor unit due to the risk of combustion or warping.

 

It  may  cause  incomplete  combustion  or  deformation  of  the      
unit due to the heat.

 

 

To  avoid  fire,  do  not  install  the  air  conditioner  where 
flammable gas may leak from.

 

If  the  gas  leaks  out  and  stays  around  the  air  conditioner,  a      
fire may break out. 

 

 

 

■ 

Ceiling-floor type

 

 

Air Outlet Horizontal Louver

 

 
 
 
 
 

 

Air Intake 
(Intake room air)

 

Air Filter 
(Filters dust)

 

 
 
 

■ 

One-way cassette type

 

 

Air Out Horizontal Louver 
(Adjust air-out direction)

 

 

Fig.2-1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.2-2

 

Children and the elderly should not operate the unit.

 

 

 

 

 

 

 

The figures show in this manual are for reference only, and the 
actual product may be different.

 

 

 

Fig.2-3

 

 

 

 

NOTE

 

Grounding Screw  
(In the control box)

 

 

Air intake 
(Intake air)

 

 

Air filter (placed 
inside the air 
intake)

 

 

Summary of Contents for KCOF-22 DN2.4

Page 1: ...r purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference Caution The heating function of an indoor unit is available only w...

Page 2: ...F 45 DN3 0 KPDF 56 DN3 0 KPDF 71 DN3 0 KPDF 80 DN3 0 KPDF 90 DN3 0 KPDF 112 DN3 0 KPDF 140 DN3 0 KPDHF 71 DN3 0 KPDHF 90 DN3 0 KPDHF 112 DN3 0 KPDHF 140 DN3 0 KPDHF 160 DN3 0 KPDHF 200 DN3 0 KPDHF 250...

Page 3: ...uch the air outlet or horizontal blades while the swing flap is in use because your fingers may become trapped or you might damage the unit Never put any objects into the air inlet or outlet Do not to...

Page 4: ...may cause water leaks Do not touch the internal parts of the controller Do not remove the front panel Some internal parts may cause injury or be damaged Never expose little children plants or animals...

Page 5: ...duced air Grille bolt lock Lock the air return grille Air deflector Control the blow out direction of the air Display panel Display status information and receive the remote controller signal Air Filt...

Page 6: ...pe Fig 2 13 Air Outlet Outlet room air Heat Exchanger Exchange cool air into warm air Air Intake Intake room air here Fig 2 11 Indoor unit Air Outlet Connects the duct ControlBox Air Intake Intakes ro...

Page 7: ...e The max temperature for the air conditioner Cooling Heating Table 3 1 Air intake Intake room air here Air filter Feet Lift up the air conditioner Filter the dust in the air Fig 2 17 Version III The...

Page 8: ...ownward air flow will cause condensation on the air outlet and louver surface Four way cassette type Cooling operation Adjust the louver horizontally Do not overcool or overheat Avoid excessive exposu...

Page 9: ...that are too steep or water will drip from the unit Adjust the air flow up and down Cooling operation Adjust the louver horizontally The louver is horizontal When heating Adjust the louver down vertic...

Page 10: ...onsole type Adjust the air direction up and down Auto swing Press SWING for the louver will swing up and down automatically Manual swing Press Air Direction to fix the louver at the desired angle The...

Page 11: ...ont panel How to open the front panel Refer to Fig 5 4 Two way cassette type Fig 4 21 Before opening the front panel turn the machine off and turn the breaker to OFF Do not touch the metal parts on th...

Page 12: ...together with the air filter as shown in Fig 5 2 Pull the air in grill down to 45 and lift it up to remove the grill Do not try to adjust the louver by hand When adjusting it by hand the mechanism ma...

Page 13: ...pe Push the grill switches in the directions of the arrows Then open the air in grill downwards Press the claws on the right and left of the air filter down slightly then pull upwards For digital scro...

Page 14: ...ly operation for about half a day to dry the interior of the unit Clean the air filter and indoor unit casing Refer to Cleaning the air filter for details on how to proceed and make sure you install c...

Page 15: ...ng sound is heard when the system stops after heating operation The expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit The air...

Page 16: ...s or stops frequently There is too much or too little refrigerant There is no gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Check...

Page 17: ...display disappears after a certain time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air conditioner operation will stop up to the set time...

Page 18: ...rm No address when powered on the first time Timer LED and run LED flash together After the fault ends the unit resumes automatically NO Type Contents Display content Remarks 1 Malfun ction Room temp...