background image

 Page 12 

Issue

Possible Causes

The outdoor unit makes 
noises

The unit will make different sounds based on its current operating mode.

Dust is emitted from 
either the indoor or 
outdoor unit

The unit may accumulate dust during extended periods of non-use, which will be emitted 
when the unit is turned on.
This can be mitigated by covering the unit during long periods of inactivity.

The unit emits a bad 
odour

The unit may absorb odours from the environment (such as furniture, cooking, cigarettes, 
etc.) which will be emitted during operations.

The unit's filters have become moldy and should be cleaned.

The fan of the outdoor 
unit does not operate

During operation, the fan speed is controlled to optimize product operation.

Summary of Contents for KCIS-71 DR11

Page 1: ...S and manufacturer information from the Owner s Manual Product Fiche in the packaging of the outdoor unit European Union Products only If used as MULTI unit please refer to the Installation Operation...

Page 2: ......

Page 3: ...g Tips c Error Codes 5 European Disposal Guidelines 16 Caution Risk of fire flammable materials WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and r...

Page 4: ...ate the defrosting process to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an...

Page 5: ...eating devices thoroughly ventilate the room to avoid oxygen deficiency Do not climb onto or place objects on top of the outdoor unit Do not operate the air conditioner when using fumigant insecticide...

Page 6: ...C 32 F 122 F 15 C 50 C 5 F 122 F For models with low temp cooling systems 18 C 54 C For special tropical models 7 C 24 C 0 C 60 C For special tropical models Fixed speed Type COOL Mode HEAT Mode DRY M...

Page 7: ...losed to keep cool or warm air in the room DO NOT place objects near the air inlet and outlet of the unit This will reduce the efficiency of the unit Set a timer and use the built in SLEEP ECONOMY mod...

Page 8: ...panel on the indoor unit can be used to operate the unit in case the remote control has been misplaced or is out of batteries MANUAL button This button selects the mode in the following order AUTO FO...

Page 9: ...m Do not wash the unit under running water Doing so creates an electrical hazard Do not use water hotter than 40 C 104 F to clean the front panel This can cause the panel to become deformed or discolo...

Page 10: ...and safety threat Refrigerant Leak Detection System some models In the event of a refrigerant leak the LCD screen will display EC and the LED indicator light will flash Preparation For Periods Of Non...

Page 11: ...he unit changes from COOL mode to FAN mode The unit changes its setting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature...

Page 12: ...h will be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odour The unit may absorb odours from the environment suc...

Page 13: ...nd windows are closed while operating the unit Excessive heat is generated by sunlight Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long ter...

Page 14: ...10 OFF E9 10 Overload protection 1 ON F0 11 Outdoor temperature sensor error 2 ON F1 12 Outdoor condenser pipe sensor error 3 ON F2 13 Discharge air temperature sensor error 4 ON F3 14 Outdoor EEPROM...

Page 15: ...flash 6 Outdoor malfunction Quick flash Quick flash E6 7 EEPROM malfunction Quick flash Quick flash E7 8 Water level alarm malfunction E8 Quick flash 9 DC motor speed out of control Quick flash Eb Qui...