Thank you for purchasing this air conditioner. This manual will provide you with information on how 

to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the 

proper function and extended lifespan of your unit.

 

Please pay attention to the following signs:

 

WARNING

 

 

CAUTION

 

 

 

ƒ

 

Page 4 

„

 

 

 

Ask an authorized dealer to install this air 

 

The warranty will be voided if the unit is not 
installed by professionals.

 

If abnormal situation arises (like burning 
smell), turn off the power supply and call 
your dealer for instructions to avoid electric 
shock, fire or injury.

 

DO NOT 

let the indoor unit or the remote 

control get wet. It may cause electric shock 
or fire.

 

DO NOT 

insert fingers, rods or other objects 

into the air inlet or outlet. This may cause 
injury, since the fan may be rotating at high 
speeds.

 

DO NOT 

use a flammable spray such as hair 

spray, lacquer or paint near the unit. This 
may cause fire or combustion.

 

Do not use means to accelerate the 
defrosting process or to clean, other than 

 

The appliance shall be stored in a room 
without continuously operating ignition 
sources (for example: open flames, an 
operating gas appliance or an operating 
electric heater).

 

The appliance shall be stored so as to 

 

WARNING

 

• 

Be aware that the refrigerants may not 
contain an odour.

 

• 

Compliance with national gas regulations 
shall be observed.

 

• 

Keep ventilation openings clear of 
obstruction.

 

• 

DO NOT 

pierce or burn.

 

• 

A warning that the appliance shall be stored 
in a well-ventilated area where the room size 
corresponds to the room area as specified 
for operation.

 

• 

Any person who is involved with working on 
or breaking into a refrigerant circuit should 
hold a current valid certificate from an 
industry-accredited assessment authority, 
which authorise their competence to handle 
refrigerants safely in accordance with an 
industry recognised assessment specification.

 

• 

Servicing shall only be performed as 
recommended by the equipment 
manufacturer. Maintenance and repair 
requiring the assistance of other skilled 
personnel shall be carried out under the 
supervision of the person competent in the 
use of flammable refrigerants.

 

Failure to observe a warning may result in death. The appliance must be 

t

 in 

 with 

tional 

t

 

 

Failure to observe a caution may result in injury or equipment damage.

 

Summary of Contents for KCI-26DMR11

Page 1: ...t Four Way Cassette KCI 26DMR11 KCI 35DR11 KCI 52DMR11 KCI 35DVN11 KCI 52DVN10 IMPORTANT NOTE Read this manual carefully before installingoroperating yournewair conditioningunit Makesuretosave this manualforfuturereference ...

Page 2: ...oor unit outdoor unit For R 410 units For R32 units KCI 35 DVN11 KCI 35 DR11 KUE 35 DVN11 KCI 52 DVN10 KCI 52 DN10 KUE 52 DVN10 Indoor Units For R 410 units For R32 units KCI 26 DMR11 KCI 35 DR11 KCI 52 DMR11 ...

Page 3: ...Table of Contents Owner s Manual SafetyPrecautions 04 Indoor Unit Parts and Major Functions 06 ManualOperations 08 ...

Page 4: ... b How to Clean the Air Filter 09 c Repairing Refrigerant Leaks 10 d Preparation for Periodsof Non use 10 Troubleshooting 11 a CommonProblems 11 b Troubleshooting Tips 12 European Disposal Guidelines 14 Caution Risk of fire flammable materials ...

Page 5: ...estoredinaroom without continuously operatingignition sources forexample openflames an operatinggasapplianceoranoperating electric heater The appliance shall be stored so as to WARNING Beawarethattherefrigerantsmaynot contain anodour Compliance with national gas regulations shall beobserved Keepventilationopeningsclearof obstruction DO NOT pierce orburn Awarningthattheapplianceshallbestored inawel...

Page 6: ...unitto see ifanythingis damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with otherheatingdevices thoroughlyventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoorunit DO NOT operate the airconditioner when using fumigant insecticides The chemicals may become layered with the unit and endangert...

Page 7: ...operation Iftheair conditioner is usedunder differentconditions it may malfunctionor becomelessefficient COOL Mode HEAT mode DRY mode Indoor Temperature 17 32 C 62 90 F 0 30 C 32 86 F 17 32 C 62 90 F 0 50 C 32 122 F Outdoor Temperature 15 50 C 5 122 F 15 24 C 5 76 F 0 50 C 32 122 F low temperature cooling models Page 6 Indoor Unit Parts And Major Functions Unit Parts ...

Page 8: ...densationmayformanddrip intothemachine Toresetthelouver pressthe manual button which will reset the horizontal louver settings Refrigerant Leak Detection System some models Intheeventofarefrigerantleak theLCDscreen willdisplay EC andtheLEDindicatorlightwill flash Energy Saving Tips DO NOT set the unit to excessive temperature levels While cooling close the curtains to avoid direct sunlight Doors a...

Page 9: ...n Thisbuttonselectsthemodeinthefollowingorder AUTO FORCEDCOOL OFF FORCED COOL mode InFORCED COOL mode the Operation lightflashes The system will then turn to AUTO after it has cooled with a high windspeed for30 minutes The remote control will be disabled during this operation OFF mode When the panel is turned OFF theunit turns off and the remote control is re enabled Page 8 Manual Operations Manua...

Page 10: ...er preventsdustandother particles from enteringtheindoor unit Dustbuildupcanreduce the efficiency of the air conditioner Foroptimum efficiency clean the air filtereverytwoweeksor morefrequentlyifyouliveinadustyarea Replace the filter with a new one if it s heavily clogged and cannot becleaned Fig 4 2 Page 9 Care and Maintenance Removing and cleaning the filter can be performed by a certified techn...

Page 11: ...les blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of the indoorunit Reinstalltheclean dryairfilterin its originalposition 3 Turnonthemainpowerswitchatleast12 hours prior to operating the unit Storing the Unit While Not In Use 1 RuntheapplianceonFANmodefor12hours in a warm room to dry it and prevent mold 2 Turn off the appliance and unplug it 3 ...

Page 12: ...set temperaturehas beenreached atwhich pointtheunitturnsoff the compressor Theunitwillresumeoperatingwhenthetemperaturefluctuates again The indoor unit emits white mist Inhumidregions alargetemperaturedifferencebetweentheroom sairand the conditioned air can cause white mist Both the indoor andoutdoorunits emit white mist WhentheunitrestartsinHEATmodeafterdefrosting whitemistmaybe emitted due to mo...

Page 13: ... or outdoor unit is dirty Clean the affected heat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Turntheunitoff remove theobstruction and turn it back on Doors and windows are open Makesurethatalldoorsandwindowsare closed while operating the unit Excessiveheat isgeneratedby sunlight Close windows and curt...

Page 14: ...on 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 On F4 15 Outdoor fan speed DC fan motor only malfunction 6 On F5 16 Inverter module IPM protection 1 Flash P0 17 High Low voltage protec...

Page 15: ...pal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will also take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Thedesignandspecificationsaresubjecttochangewithoutpriornoticeforproduct improvement Consult with the sales agency or manufacturer for details QSBPQ...

Page 16: ......