Correct orientation of Mounting Plate
Abertura con cubierta de plástico
24k
9k, 12k, 18k
Page 20
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates. For
the different customization requirements, the shape
of the mounting plate may be slightly different. But the
installation dimensions are the same for the same size of
indoor unit.
See Type A and Type B for example:
NOTE:
When the gas side connective pipe is Ø 16mm
(5/8in) or more, the wall hole should be 90mm (3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating sleeve
attached to the back of the unit. You must prepare
the piping before passing it through the hole in the
wall.
1.
Based on the position of the wall hole relative to
the mounting plate, choose the side from which the piping
will exit the unit.
2.
If the wall hole is behind the unit, keep the knock-
out panel in place. If the wall hole is to the side of the
indoor unit, remove the plastic knock-out panel from that
side of the unit. This will create a slot through which your
piping can exit the unit. Use needle nose pliers if the
plastic panel is too difficult to remove by hand.
3.
If existing connective piping is already embedded
in the wall, proceed directly to the Connect Drain Hose
step. If there is no embedded piping, connect the indoor
unit's refrigerant piping to the connective piping that will
join the indoor and outdoor units. Refer to the Refrigerant
Piping Connection section of this manual for detailed
instructions.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from four
different angles: Left-hand side, Right-hand side, Left
rear, Right rear.
CAUTION
Be extremely careful not to dent or damage the piping
while bending them away from the unit. Any dents in the
piping will affect the unit's performance.