background image

Closing curtains during heating also helps 

keep the heat in

Doors and windows should be kept closed

 Page 9 

•  The air conditioner turns to FAN ONLY mode 

from COOL or HEAT mode

 (for cooling and heating 

models only)
When the indoor temperature reaches the set 
temperature setting, the compressor will stop 
automatically, and the air conditioner turns to FAN only 
mode. The compressor will start again when the indoor 
temperature rises on COOL mode or falls on HEAT 
mode to the set point.
Droplets of water may form on the surface of the indoor 
unit when cooling occurs in relatively high humidity 
(defined as high than 80%). Adjust the horizontal 
louver to the maximum air outlet position and select 
HIGH fan speed.

•  Heating mode

 (for cooling and heating models only)

The air conditioner draws in heat from the outdoor unit 
and releases it via the indoor unit during heating. When 
the outdoor temperature falls, heat drawn in by the air 
conditioner decreases accordingly. At the same time, 
heat loading of the air conditioner increases due to larger 
difference between indoor and outdoor temperature. 
If a comfortable temperature cannot be achieved with 
the air conditioner alone, it is recommended that you 
use a supplementary heating device.
Lightning or a car wireless telephone operating neraby 
may cause the unit to malfunction. Disconnect the unit 
from its power source and then re-connect the unit 
with the power source again. Push the ON/OFF button 
on the remote controller to restart operations.

Energy Saving Tips

•  DO NOT

 set the unit to excessive temperature levels.

•  While cooling, close the curtains to avoid direct sunlight.
•  Doors and windows should be kept closed to keep cool or warm air in the room.

•  DO NOT

 place objects near the air inlet and outlet of the unit. This will reduce the efficiency of the unit.

•  Set a timer and use the built-in SLEEP/ECONOMY mode if applicable.
•  If you don't plan to use the unit for a long time, remove the batteries from the remote control.
•  Clean the air filter every two weeks. A dirty filter can reduce cooling or heating efficiency.
•  Adjust louvers properly and avoid direct airflow.

Summary of Contents for KAM2-42 DN8

Page 1: ...ference This manual only describes the outdoor unit of user s When using the indoor unit refer to the user s manual of indoor unit OWNER S MANUAL Outdoor Units R 410A R 32 KAM2 42 DN8 KAM2 52 DN7 KAM3...

Page 2: ......

Page 3: ...for R 32 Refrigerant only WARNING Servicing shall only be perfomed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be car...

Page 4: ...ll be stored so as to prevent mechanical damage from occurring Be aware that the refrigerants may not contain an odour 0 Safety Precautions Compliance with national gas regulations shall be observed K...

Page 5: ...he indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroughly ventilate the room...

Page 6: ...ing filter Air filter behind 5 Horizontal louver 6 LCD display window 7 Vertical louver 8 Manual control button behind 9 Remote controller holder Outdoor unit 10 Drain hose refrigerant connecting pipe...

Page 7: ...taining air filter 3 Remote controller 4 Installation part 5 Display panel Outdoor unit 6 Drain hose refrigerant connecting pipe 7 Connective cable 8 Stop valve 9 Fan hood Fig 2 4 Indoor unit 1 Drain...

Page 8: ...resulting in lower heating efficiency in the air conditioner Under these conditions the air conditioner will stop heating operations and start defrosting automatically The time to defrost may vary fr...

Page 9: ...gly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature cannot be achieved with the air conditio...

Page 10: ...odically Contact a local dealer of a customer service centre if the unit requires NOTE Before you clean the air conditioner be sure to switch off the unit and disconnevy the power supply plug Optimal...

Page 11: ...st the unit In Cooling only Models If the Fan Only indicator is lit up the outdoor temperature is too cold and the unit s anti freeze protection is activated in order to defrost the unit The unit chan...

Page 12: ...different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when...

Page 13: ...oors and windows are closed while operating the unit Excessive heat is generated Close windows and curtains during periods of high heat or bright sunshine Low refrigerant due to leak or long term use...

Page 14: ...disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take bac...

Page 15: ...hange without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the late...

Page 16: ......

Reviews: