Base pan hole of
outdoor unit
Seal
Seal
Drain joint
(A)
(B)
Admisión de aire
Air inlet
Air outlet
Page 25
IN COLD CLIMATES
In cold climates, make sure that the drain hose is as
vertical as possible to ensure swift water drainage. If
water drains too slowly, it can freeze in the hose and flood
the unit.
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground or to
a wall-mounted bracket with bolt (M10). Prepare the
installation base of the unit according to the dimensions
below.
UNIT MOUTING DIMENSIONS
The following is a list of different outdoor unit sizes and
the distance between their mounting feet. Prepare the
installation base of the unit according to the dimensions
below
Outdoor Unit Dimensions (mm)
Mounting Dimensions
A x H x F
Distance A (mm)
Distance B (mm)
681 x 434 x 285 (26,8" x 17,1" x 11,2")
460 (18,1")
292 (11,5")
700 x 550 x 270 (27,5" x 21,6" x 10,6")
450 (17,7")
260 (10,2")
700 x 550 x 275 (27,5" x 21,6" x 10,8")
450 (17,7")
260 (10,2")
720 x 495 x 270 (28,3" x 19,5" x 10,6")
452 (17,7")
255 (10,0")
728 x 555 x 300 (28,7" x 21,8" x 11,8")
452 (17,8")
302 (11,9")
765 x 555 x 303 (30,1" x 21,8" x 11,9")
452 (17,8")
286 (11,3")1
770 x 555 x 300 (30,3" x 21,8" x 11,8")
487 (19,2")
298 (11,7")
805 x 554 x 330 (31,7" x 21,8" x 12,9")
511 (20,1")
317 (12,5")
800 x 554 x 333 (31,5" x 21,8" x 13,1")
514 (20,2")
340 (13,4")
845 x 702 x 363 (33,3" x 27,6" x 14,3")
540 (21,3")
350 (13,8")
890 x 673 x 342 (35,0" x 26,5" x 13,5")
663 (26,1")
354 (13,9")
946 x 810 x 420 (37,2" x 31,9" x 16,5")
673 (26,5")
403 (15,9")
946 x 810 x 410 (37,2" x 31,9" x 16,1")
673 (26,5")
403 (15,9")