2 0 H a M e s i l a S t . , N e s h e r 3 6 8 8 5 2 0 , I s r a e l
P O B 2 5 0 0 4 , H a i f a 3 1 2 5 0 0 1 , I s r a e l
T e l : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 0 0 F a x : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 1 1
Page no. 38 | Appendix No. 1
8.11.2
lut_mode <mode>
Selects the LUT operational mode which are described in the following table:
Mode
Description
0
Table based using interpolation. The user has to specify a table with a maximum of 48 values.
Intended for offline calibration.
1
Fast gamma mode where the user only specifies the desired gamma value.
Can be used for gamma changes during runtime.
2
Fixed gamma mode where the user selects one of three fixed gamma tables.
8.11.3
lut_preset <index>
Selects the preset storage for the current LUT interpolator. There are up to 5 presets which can be modified.
Index
Factory preset
0
Linear
1
Linear
2
Linear
3
Linear
4
Linear
Example:
// Select lut preset 1
lut_preset 1
8.11.4
lut_sample_master <xi_0> <yi_0> ... <xi_7> <yi_7>
Defines the sample points in a lookup table for all colors. The x-value is the input value, the y-value is output.
Value
Minimal
Maximal
xi_n
0
5904
Yi_n
0
5904
Sets up to 8 sample points at a time, up to a total of 54 for the look up definition for all colors. For setting more
than 8 points, the function can be called multiple times. In case a x-position is set twice, the previous value is
overwritten.
Remarks:
1.
When more than 54 points are defined, an error message is dumped.
2.
lut_sample_<color> command should be used to read back the current sample point. lut_sample_master will
not return sample data.