9
F G
INFRARED HANDHELD MICROPHONE ILLUSTRATION
Please avoid your hand covering the top emitter and bottom emitter
1.
Select a channel by A/B Channel Switch (9)
*
*
A CH -> Channel A (2.3 MHz)
B CH -> Channel B (2.8 MHz)
2.
Select output power by HI/LOW Selector (12)
*
*
HI -> Distance can reach to 20 M; power consumption around 300 mA
LOW -> Distance can reach to 15 M; power consumption around 200 mA
4.
Switch the button (8) to the Talk status when you intend to amplifier your speach;
switch the button (8) to the Mute status when you are temperately not using the
microphone.
Insufficient power influences the signal transmission. We
recommend you using the capacity 2500 mAh rechargeable
batteries and dual-slot charger HDC-502 as the best
solution.
6.
5.
Press the power switch button (5) for 4~5 seconds to
turn the device off.
HDC-502
3.
After battery installation and close the battery door, press the power switch button
(5) for 1 second, and then the power indicator (4) lights up to show the device
being on.
*
*
Lights green: power sufficient
Lights red: power insufficient; please prepare new batteries or recharging
procedure
CAUTION !
Only Ni-MH rechargeable batteries are allowed to be charged. It may cause
leakage or explosion when charging un-rechargeable batteries.
Please take out batteries if the unit isn’t in use for a long time to avoid battery
leakage.
Operation Indication of EJ-501TI
Correctly hand EJ-501TI