9 Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:
KaVo provides the end customer with a warranty of proper function and guarantees
zero defects in respect of material and processing for a period of 12 months from the
date of the invoice, subject to the following conditions:
In case of justified complaints, KaVo will honour its warranty with a free replacement
or repair. Other claims of any nature whatsoever, in particular with respect to compen‐
sation, are excluded. In the event of default, gross negligence or intent, this shall only
apply in the absence of mandatory legal regulations to the contrary.
KaVo shall not be liable for defects and their consequences that have arisen or may
arise from natural wear, improper handling, cleaning or maintenance, non-compliance
with operating, maintenance or connection instructions, calcination or corrosion, con‐
taminated air or water supplies or chemical or electrical factors deemed abnormal or
impermissible in accordance with KaVo's instructions for use or other manufacturer's
instructions. The warranty granted does not usually extend to lamps, light conductors
made of glass and glass fibres, glassware, rubber parts, and the colourfastness of
plastic parts.
All liability is excluded if defects or their consequences originate from manipulations or
changes to the product made by the customer or a third party that is not authorised by
KaVo.
Warranty claims will only be accepted if the product is submitted along with proof of
purchase in the form of a copy of the invoice or note of delivery. The dealer, purchase
date, type, and serial number must be clearly evident from this document.

 

Summary of Contents for PROPHYflex 3

Page 1: ...Instructions for use PROPHYflex 3 2018 1 000 4672 1 006 9926 1 006 9928 Always be on the safe side...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...HYflex Pulver PROPHYpearls PROPHY Superpearls PROPHYflex Perio Powder 13 6 Troubleshooting 18 6 1 Cleaning a blocked cannula 18 6 2 Cleaning the main body 18 7 Preparation methods according to ISO 176...

Page 4: ...KaVo Dental GmbH Refer to the chapter on Safety Warning symbol Important information for users and service technicians Can be steam sterilised at 134 o C 1 o C 4 o C 273 o F 1 6 o F 7 4 o F Thermodis...

Page 5: ...erty damage and injury CAUTION CAUTION indicates a hazardous situation that can cause damage to property or mild to moder ate injuries WARNING WARNING indicates a hazardous situation that can lead to...

Page 6: ...a salt free or low salt diet patients with renal insufficiency chronic diseases of the respiratory sys tem and chronic diarrhoea In such cases check if an alternative treatment with PROPHYpearls or PR...

Page 7: ...entist does not unnecessarily inhale the powder Note The patient should rinse his or her mouth with water after treatment Note After successful treatment with the PROPHYflex all tooth surfaces should...

Page 8: ...dentistry Please refer also to the Instructions for Use A medical device according to relevant national statutory regulations Proper use According to these regulations this medical device may only be...

Page 9: ...earls 1 P nozzle G 1 x P nozzle K recess 3 4 Transportation and storage conditions CAUTION It is hazardous to start up the medical device after it has been stored strongly refriger ated This can cause...

Page 10: ...lex LUX MULTIflex LED coupling onto the turbine hose and tighten with the wrench The water fraction of the spray can be controlled through rotating the spray ring on the MULTIflex LUX MULTIflex LED co...

Page 11: ...1 006 9926 1 006 9928 4 Start up and shut down 4 4 Check O rings 4 4 Check O rings CAUTION Missing or damaged O rings Malfunctions and premature failure Make sure that all O rings are on the coupling...

Page 12: ...s secure by pulling on it 5 2 Remove the medical device Hold the coupling tight and pull the medical device off while twisting slightly 5 3 Filling the powder container Unscrew the powder container to...

Page 13: ...ION The marks must be adjacent otherwise the cannula can come loose If the cannula comes off during treatment it could substantially endanger the patient and user Pull on the cannula each time before...

Page 14: ...OPHYflex powder CAUTION Hazard from the use of PROPHYflex on the gingiva The gingiva may be damaged Do not direct the powder jet toward the gingiva Always work from pink to white The front part of the...

Page 15: ...red local amount as the red is re moved The jet should not directly contact the gingival margin exposed tooth necks or the mucosa The handpiece tip should be held approximately 3 5 mm from the sur fac...

Page 16: ...ter mixture is pro duced Getting the patient ready Apply some Vaseline ointment to the patient s lips This prevents the lips from becoming dry and cracking Hook the small saliva ejector into the corne...

Page 17: ...5 Operation 5 6 Instructions for use for PROPHYflex Pulver PROPHYpearls PROPHY Superpearls PROPHYflex Per io Powder 30 60 Glycine PROPHYflex Perio Powder working angle 30o to 60o During the treatment...

Page 18: ...eaned with a cloth once per week 6 1 Cleaning a blocked cannula Remove the cannulas Twist the nozzle needle from the front and then from the back into the cannula The remove the nozzle needle and blow...

Page 19: ...olution or similar 7 2 Cleaning CAUTION Malfunctions from cleaning in the ultrasonic unit Defects in the product Only clean manually or in a thermodisinfector 7 2 1 Manual cleaning of the exterior Req...

Page 20: ...ng agents with a pH value of max 10 e g Miele G 7781 G 7881 Validation was carried out with Programme VARIO TD cleaning agent neodisher mediclean neutralisation agent neodisher Z and rinsing agent neo...

Page 21: ...ies to the material compatibility with KaVo prod ucts For program settings as well as cleansers and disinfectants to be used please re fer to the Instructions for Use of the thermodisinfector complyin...

Page 22: ...ticlockwise and drain and clean it before each thermal disinfection or sterilisation Do not screw the powder container back on be fore thermal disinfection or sterilisation Likewise clean off any powd...

Page 23: ...Powder berry Pack of 80 sticks Mat no 1 007 0015 PROPHYflex Powder cherry Pack of 80 sticks Mat no 1 007 0016 PROPHYflex Powder mint Pack of 80 sticks Mat no 1 007 0017 PROPHYpearls neutral Pack of 80...

Page 24: ...le for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions cal...

Page 25: ......

Page 26: ...1 000 6601 kb 20140210 07 en...

Reviews: