background image

Instructions for use

K-POWERgrip Handstück 4941

Always be on the safe side.

Summary of Contents for K-POWERgrip

Page 1: ...Instructions for use K POWERgrip Handst ck 4941 Always be on the safe side...

Page 2: ...Sales KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Tel 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...General information 6 2 2 2 Product specific 7 2 2 3 Disposal of electronic and electrical devices 7 2 3 Safety instructions 8 2 3 1 General information 8 2 3 2 Product specific 10 3 Product descript...

Page 4: ...Use CI Care instructions AI Assembly instructions TI Technician s instructions SC Safety checks IEC International Electrotechnical Commission RI Repair instructions EMC Electromagnetic compatibility 1...

Page 5: ...fibres glassware rubber parts and the colourfastness of plastic parts The warranty expires if defects or their consequences could possibly have arisen because the product has been modified or changed...

Page 6: ...th any of the above obligations will mean that the damage will be considered to have arisen following delivery in accordance with ADSp Art 28 Outside Germany Note KaVo is not liable for damage arising...

Page 7: ...n Note Please keep the packaging should you need to return the product for servicing or repair The symbols printed on the outside are for transportation and storage and have the following meaning Tran...

Page 8: ...levels are used in this document to prevent personal and property damage CAUTION CAUTION indicates a hazardous situation that can cause damage to property or mild to moderate injuries WARNING WARNING...

Page 9: ...r the applicable health and safety regulations the applicable accident prevention regulations 2 2 2 Product specific The K POWERgrip handpiece 4941 is for working on crowns bridges and plastic and cas...

Page 10: ...vice will bear the costs for disassembly transpor tation and packaging International EU For country specific information on disposal contact your dental supplier 2 3 Safety instructions 2 3 1 General...

Page 11: ...notify service technician Check the electrode lines and accessories for damage to the insulation CAUTION Damage due to liquids Faults on electric components Protect product openings from penetration...

Page 12: ...ION Risk of injury due to rotating tools Eye injury Wear safety glasses Use protective shield CAUTION Unsuitable speed Damage to the product Problems processing selected material Check the speed setti...

Page 13: ...ver Straight pin Grip tip Handpiece part Motor part Cable Chuck 3 2 Scope of delivery Figure Name Material number K POWERgrip hand piece 4941 Mat no 1 002 2916 Servicing set Mat no 0 411 3180 Instruct...

Page 14: ...nvironmental conditions Permissible ambient temperature range 5 C to 40 C Permissible to maximum relative hu midity 80 Exposure mode Operating time 2 minutes ON Pause time 8 minutes OFF Requirements c...

Page 15: ...r pressure 700 hPa to 1060 hPa Note Prior to start up very cold products must be heated to a temperature of Heat to 20 C to 25 C Avoid condensation Instructions for use K POWERgrip Handst ck 4941 3 Pr...

Page 16: ...piece must be approved by KaVo Note When it is new you can hear a soft irregular clicking or buzzing at high speeds of the micromotor This bearing noise is completely normal and disappears as soon as...

Page 17: ...have inserted the tool insert the tool as far as it will go tool shaft length minimum 16 mm you need to check the functionality of the chuck KaVo recommends a grip test at 50 N Note Only use tools tha...

Page 18: ...Operate the handpiece as specified in the instructions for use of the upstream control unit Instructions for use K POWERgrip Handst ck 4941 5 Operation 5 2 Operation 16 29...

Page 19: ...vice from the power con nection to de energize the device CAUTION Ingress of dust or liquids into the handpiece Damage to ball bearings and O rings Never use compressed air or cleaning agents such as...

Page 20: ...til the clamp B can be inserted with a slight amount of resistance into the grip tip Open the chuck Shove out the chuck with the original chuck key A while the pin or tool is inser ted Clean the front...

Page 21: ...obe into the chuck as far as it will go Grip the handpiece part 2 and turn the motor 3 in the direction indicated by the arrow until the chuck closes completely 6 2 Servicing 6 2 1 Replacing ball bear...

Page 22: ...felt washer entnehmen Grasp the handpiece part and loosen and remove the threaded ring with the socket wrench E Use the wrench to completely remove the shaft from the handpiece Remove the ball bearin...

Page 23: ...nut onto the shaft Hold the shaft with the wrench D and screw the nut tight with the socket wrench E note left hand thread Shove the ball bearing O rings to the insive of the handpiece and sleeves an...

Page 24: ...ully tight en with the clamp B Insert the cover B Note To increase the service life of the ball bearings KaVo recommends the following After changing the ball bearing let the handpiece idle for about...

Page 25: ...sert a new 3 pole line into the motor part and screw in the cap with the wrench D Note Check the functionality of the handpiece Instructions for use K POWERgrip Handst ck 4941 6 Service and Care 6 2 S...

Page 26: ...k the controls and have them repaired if necessary The tool is not tightly held by the chuck Tool shaft and chuck diameters are not the same Use a tool chuck with a suitable diameter The chuck is loos...

Page 27: ...entation Material summary Mat no Handpiece rest 0 642 0352 Chuck 30 mm 0 674 4881 Chuck 2 35 mm 0 674 4871 Key D 0 411 3962 Socket wrench E 0 411 2310 Instructions for use K POWERgrip Handst ck 4941 8...

Page 28: ...6095 1 002 3648 0 200 6219 1 002 3600 0 200 6320 0 200 6155 0 674 8962 0 674 8982 0 220 0779 0 220 0778 B 1 002 3644 0 674 8472 0 223 0111 0 223 0396 0 674 8972 0 224 7048 0 674 7392 0 200 1045 0 223...

Page 29: ...674 8752 0 674 4511 AT 1 001 5629 0 200 6095 0 220 0044 0 674 7602 0 200 6303 0 674 7642 0 674 8732 0 674 9002 0 200 0826 1 000 3586 0 674 8772 0 222 4044 0 200 1252 0 410 0732 A 0 200 6323 1 000 1260...

Page 30: ...10 Statement of conformance Instructions for use K POWERgrip Handst ck 4941 10 Statement of conformance 28 29...

Page 31: ...Instructions for use K POWERgrip Handst ck 4941 10 Statement of conformance 29 29...

Page 32: ......

Page 33: ...1 007 1541 Fk 20110817 02 en...

Reviews: