9

   

Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:

KaVo provides the end customer with a warranty of proper function and guaran‐

tees zero defects in respect of material and processing for a period of 12 months

from the date of the invoice, subject to the following conditions:

In case of justified complaints, KaVo will honour its warranty with a free replace‐

ment or repair. Other claims of any nature whatsoever, in particular with respect

to compensation, are excluded. In the event of default, gross negligence or intent,

this shall only apply in the absence of mandatory legal regulations to the contrary.

KaVo shall not be liable for defects and their consequences that have arisen or

may arise from natural wear, improper handling, cleaning or maintenance, non-

compliance with operating, maintenance or connection instructions, calcination or

corrosion, contaminated air or water supplies or chemical or electrical factors

deemed abnormal or impermissible in accordance with KaVo's instructions for use

or other manufacturer's instructions. The warranty granted does not usually ex‐

tend to lamps, light conductors made of glass and glass fibres, glassware, rubber

parts, and the colourfastness of plastic parts.

All liability is excluded if defects or their consequences originate from manipula‐

tions or changes to the product made by the customer or a third party that is not

authorised by KaVo.

Warranty claims will only be accepted if the product is submitted along with proof

of purchase in the form of a copy of the invoice or note of delivery. The dealer,

purchase date, type, and serial number must be clearly evident from this docu‐

ment.

 

 

 

Instructions for use COMPACTtorque 636 - 0.553.0810 COMPACTtorque 636C - 0.553.0830
9 Terms and conditions of warranty

22/22

Summary of Contents for COMPACTtorque 636

Page 1: ...Instructions for use COMPACTtorque 636 0 553 0810 COMPACTtorque 636C 0 553 0830 Always be on the safe side...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 0 7351 56 0 Fax 49 0 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...7 2 1 Manually cleaning the outside 13 7 2 2 Automated external cleaning 13 7 2 3 Manually cleaning the interior 14 7 2 4 Automated internal cleaning 14 7 3 Disinfection 14 7 3 1 Manually disinfectin...

Page 4: ...n for users and service technicians Can be steam sterilised at 134 C 1 C 4 C 273 F 1 6 F 7 4 F Thermodisinfectable CE mark European Community A product bearing this mark meets the requirements of the...

Page 5: ...ardous situation that can cause damage to property or mild to moderate injuries WARNING WARNING indicates a hazardous situation that can lead to serious or fatal injury DANGER DANGER indicates a maxim...

Page 6: ...e should be cleaned serviced and stored in a dry location according to instructions before long periods of nonuse Note For safety reasons we recommend that the tool holder system be checked an nually...

Page 7: ...national statutory regulations Proper use According to these regulations this medical device may only be used for the de scribed application by a knowledgeable user The following must be observed the...

Page 8: ...with 4 hole connec tions 3 3 Transportation and storage conditions CAUTION It is hazardous to start up the medical device after it has been stored strongly refrigerated This can cause the medical devi...

Page 9: ...and moist cooling air Contaminated and moist cooling air can cause malfunctions and lead to prema ture bearing wear Make sure that the supply of cooling air is dry clean and uncontaminated ac cording...

Page 10: ...bearing wear Ensure that the cooling air is dry clean and uncontaminated in accordance with EN ISO 7494 2 A minimum drive pressure of 2 1 bar 30 psi is required for operating the medical device The ai...

Page 11: ...hen the seal is damaged it can cause malfunctions or premature failure Check if the medical device is sealed and undamaged Instructions for use COMPACTtorque 636 0 553 0810 COMPACTtorque 636C 0 553 08...

Page 12: ...t do not deviate from the specified data CAUTION Injury from using worn cutters or grinders Cutters or grinders can fall out during treatment and injure the patient Never use cutters or grinders with...

Page 13: ...nder is rotating If you press the pushbutton when the cutter or grinder is rotating it can damage the chucking system and cause injury Never touch soft tissue with the head or tip since it may be hot...

Page 14: ...o overheat and damage the tooth Check spray water channels and if necessary clean spray nozzles with the nozzle needle Mat no 0 410 0921 Use the nozzle needle Mat no 0 410 0921 to free the water passa...

Page 15: ...side Accessories required Tap water 30 C 5 C 86 F 10 F Brush e g medium hard toothbrush Brush off under flowing tap water 7 2 2 Automated external cleaning KaVo recommends thermodisinfectors in accord...

Page 16: ...modisinfec tors in accordance with EN ISO 15883 1 7 2 4 Automated internal cleaning KaVo recommends thermodisinfectors in accordance with EN ISO 15883 1 which are operated with alkaline cleaning agent...

Page 17: ...lubricate the KaVo medical device im mediately with care agents from the KaVo care system 7 3 3 Mechanically disinfecting the exterior and interior KaVo recommends thermodisinfectors in accordance wit...

Page 18: ...ng and care Reduced product life Perform proper care regularly Note KaVo only guarantees that its products will function properly when the care prod ucts used are those listed as accessories as they w...

Page 19: ...Unscrew the COMPACTtorque turbine from the hose Cover the product with the Cleanpac bag Insert the tip of the spray nipple into the large tube and press the spray but ton See also Instructions for us...

Page 20: ...2104A Remove the cutter or grinder place the spray nipple tip in the opening and spray Subsequently treat with the care products and care systems specified See also Servicing with KaVo QUATTROcare 210...

Page 21: ...front door and start theservice procedure Option 2 After three minutes with no service procedure running the device auto matically switches back to normal service mode See also Care with KaVo QUATTRO...

Page 22: ...nutes at 134 C 1 C 4 C 273 F 1 6 F 7 4 F Autoclave using the gravity method at least 10 minutes at 134 C 1 C 4 C 273 F 1 6 F 7 4 F or alternatively at least 90 minutes at 121 C 1 C 4 C 250 F 1 6 F 7 4...

Page 23: ...10 0921 MULTIflex spray head nozzle 0 411 9921 Material summary Mat no Adaptor INTRAmatic CLEANspray and DRYspray 1 007 1776 KaVo CLEANspray 2110 P 1 007 0579 KaVo DRYspray 2117 P 1 007 0580 KaVo Spra...

Page 24: ...nce non compliance with operating maintenance or connection instructions calcination or corrosion contaminated air or water supplies or chemical or electrical factors deemed abnormal or impermissible...

Page 25: ......

Page 26: ...0 589 2232 kb 20130408 02 en...