Instructions for use ARCUSevo3 Product description
|
3.3 Scope of delivery
Figure
Designation
ARCUSevo facial bow incl.
Earbuds
Nose support
Reference pointer
Bite fork support
Bite fork
Instructions for use
14/24
Page 1: ...Instructions for use ARCUSevo Always be on the safe side...
Page 2: ...Sales KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Tel 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...
Page 3: ...ture 8 2 1 3 Description of hazardous steps 8 2 2 Proper use 9 2 2 1 General information 9 2 2 2 Product specific 10 2 3 Safety 11 2 3 1 General information 11 3 Product description 12 3 1 ARCUSevo 12...
Page 4: ...ions TA Technician s instructions STK Safety check IEC International Electrotechnical Commission RA Repair instructions EMC Electromagnetic compatibility 1 1 2 Symbols See the section Safety Warning S...
Page 5: ...evo 1 User instructions 1 2 Service 1 2 Service Service hotline 49 7351 56 1600 Service Zahntechnik kavo com Please indicate the product serial number in all requests Additional information can be obt...
Page 6: ...nces that are or may be due to natural wear improper handling cleaning or maintenance non compliance with operating or connection instructions calcination or corrosion contaminated air or water suppli...
Page 7: ...tion damage In Germany If external damage to the packaging is visible upon delivery follow the procedure below 1 The recipient must record the loss or damage in the notice of delivery The re cipient a...
Page 8: ...e notice of delivery The recipient can only assert damages against the transportation company ba sed on these records 2 Leave the product and packaging unchanged 3 Do not use the product If the produc...
Page 9: ...for returning the product for service or repairs The symbols printed on the outside are for transportation and storage and have the following meaning Transport upright with the arrows pointing upward...
Page 10: ...optional step contains necessary measures for avoiding hazards 2 1 3 Description of hazardous steps Safety instructions with three hazard levels are used in this document for avoiding personal and pro...
Page 11: ...personnel of authorised distributors The unit is operated in accordance with the instructions for use care and instal lation The IT components supplied by the operator meet the technical requirements...
Page 12: ...isposal Note The waste that arises must be recycled or disposed of in a manner safe for humans and the environment Observe the applicable national regulations Please direct all questions regarding the...
Page 13: ...ury or damage from damaged functional parts When functional parts are damaged it can cause additional damage or personal injury When operating parts are damaged Stop working and eliminatethe damage or...
Page 14: ...stening nut of the bite fork support Fastening nut for the earbud Adjustment wheel for adjusting the facial width Earbud Bite fork support Nose support Knurled screw of the bite fork support Lock leve...
Page 15: ...300 mm Height 100 mm Weight 250 g Weight of bite fork bite fork support 100 g Information on the planes and reference points Frankfurter horizontal FH Connection between the infraorbital point and por...
Page 16: ...use ARCUSevo 3 Product description 3 3 Scope of delivery 3 3 Scope of delivery Figure Designation ARCUSevo facial bow incl Earbuds Nose support Reference pointer Bite fork support Bite fork Instructio...
Page 17: ...uctions for use ARCUSevo 4 Operation 4 1 Adapting the facial bow 4 Operation 4 1 Adapting the facial bow Turn the adjustment wheel The earbuds move further apart The bow can be placed on the patient 1...
Page 18: ...prepared bite fork in the patient s mouth Adapt the bow to the width of the patient s face See also 4 1 Adapting the facial bow Page 15 Insert the earbuds into the outer auditory channel of the patie...
Page 19: ...k Suspend the bite fork support on the facial bow and tighten it with the fastening nut Make sure that the guide pins of the bite fork support engage in the guide groove of the facial bow See also fol...
Page 20: ...ver of the nose support push back the nose support and fix Turn the setting wheel to remove the earbuds of the facial bow from the ears Completely remove the facial bow from the patient with bite fork...
Page 21: ...membrane must be steri lized after use The following components must be sterilized Normal bite fork Mat no 0 622 0911 5 1 Cleaning 5 1 1 Manual cleaning Before sterilization clean the bite fork under...
Page 22: ...5 Preparation methods DIN EN ISO 17664 5 2 Disinfection 5 2 Disinfection 5 2 1 Manual disinfection Allowed disinfectants Microcide liquid Sch lke Mayr Wipe disinfect all components 5 2 2 Automated dis...
Page 23: ...use ARCUSevo 5 Preparation methods DIN EN ISO 17664 5 3 Sterilisation 5 3 Sterilisation Sterilise the bite fork in a fractionated initial vacuum at 134 C 1 C 3 04 bar for 4 minutes sterilisable up to...
Page 24: ...Instructions for use ARCUSevo 6 Accessories 6 Accessories Designation Material number 1 pair of adjustable axial pins 1 004 7640 22 24...
Page 25: ...Verk Nr Gesichtsbogen ARCUSevo 11 2007 09 30 1 004 7623 1 004 7637 0 258 1442 0 622 2852 0 258 6030 A A 0 622 2862 0 252 4020 0 622 2872 0 622 2192 0 622 2182 0 622 2752 0 240 2240 0 622 2772 0 252 3...
Page 26: ...Instructions for use ARCUSevo 7 Spare parts sheet 24 24...
Page 27: ......
Page 28: ...1 006 1320 Fk 20071217 01 en...