SatelLink
z
USER MANUAL
DCM000000052
Printed: 03.06.19,16:02
Revision Date:6/19/03
13
Normal Operation
The
LSU Head-End Module
has one LED on the faceplate:
1. OPERATING - Normally this LED will be GREEN.
The
LSU Remote Module
has three LED’s on the faceplate:
1. OPERATING - Normally this LED will be GREEN.
2. FAULT – Red LED, If the internal diagnostics for the module detect a
problem, then this LED will remain on
3. LASERS ON - This LED will be GREEN when any one of the three Lasers
are operating.
Configuration
It is possible to re-configure the
LNKFIB-R01 Remote Module
in the field, either
with a
Personal Computer (PC)
or via the optional
LinkNet Control Module
. To
use a
PC
it is necessary to connect the DB9 RS-232 connector on the Module to a
standard DB9 RS232 Connector on the PC. On the PC a terminal emulation
program such as
HyperTerminal
is used to communicate to the LinkNet Module.
The settings are 9600 baud, 8 bits, no parity, and 1 stop bit. Commands are one or
two words followed by pressing
Return
. Commands may be given in upper or lower-
case. Available commands are...
ACCESS USER
:
Required as a simple password to gain access to customer
settable parameters and diagnostics; This will time-out after 10
minutes, and may have to be re-typed.
HELP or ?
:
Displays a list of Available Commands.
LIST
:
Displays Current Settings and Status Faults, Etc.
VER
:
Display the current Version of Software.
ENABLE 1 or 0
:
Enables or Disables the Module.
GAINPCS ###:
Displays or Sets the PCS Transmit Gain (in tenths of a dB).
GAINCELL ###:
Displays or Sets the Cellular Transmit Gain (in tenths of a dB).
GAINPAGE ###:
Displays or Sets the iDEN and Paging Transmit Gain (in tenths of
a dB).
Please consult Kaval Wireless Technologies for further support.