Fault
Possible cause
Correction
Oil leakage
Leaking
Screw fitting is leaking
Tighten / seal screw fitting
Sealing kit defective
Replace sealing kit
Piston rod scored
Replace piston rod and
sealing kit
Solenoid valve
Not functioning
Solenoid coil defective
Replace solenoid coil
No power to the magnet
Inspect power cable and
connections