background image

Temperature & Humidity Controller -40~120C, 

0~100%RH 12VDC 

Model:XH-M452 

User Manual

 

 

How to Control the Humidity:

 

Humidification / dehumidification mode setting method: 
1. Set [start humidity]: press and hold the “+” key to start the humidity value flashing, and set the 
start humidity value with +/- key. 
2. Set [stop Humidity]: press and hold the "-" key to stop the humidity value from flashing. Use the 
+/- keys to set the stop humidity value. 
  

How to Control the Temperature: 

1. Set start tempe: 
under the normal display state, long press the "+" button for 3 seconds, the start temperature value 
flashes, press +/- key to set the value, after 5 seconds without operation, automatically return to the 
detection temperature display. 
  
2. Set the stop temperature: 
under the normal display state, long press the "-" button for 3 seconds to stop the flashing of the 
temperature value. Press the +/- button to set the value. 
  
3. Restore factory settings: 
at the same time long press the temperature key and humidity "+" button for 3 seconds, digital 
display 888888 
  

Heating/cooling Mode Setting Method: 

1. Setting method: start temperature < stop temperature (program automatically determines 
operating mode as heating mode). 
2. Setting method: start temperature > stop temperature (program automatically determines the 
operating mode as cooling mode) 