Technical data of the antennas
Type
AOI 65
AON 65
AOP 65
Order Number
212340
212344
212348
Channels
21-69
21-69
21-69
Gain
dB
7-9.5
8.5-13.5
9.5-15
Reception range
MHz
470-862
470-862
470-862
Full width at half maximum Horiz.
Vert.
°
°
58-40
90-65
57-32
70-44
50-28
59-31
Front-to-back-ratio
dB
20-25
21-26
22-28
Mast clamp range
Ø mm
22-60
22-60
22-60
Length
mm
410
814
1345
Wind load at 800 N/m
2
N
40
59
106
Limiting wind load at 1100 N/m
2
N
55
81
146
Packing unit/weight
P./kg
1/1.0
1/1.8
1/2.4
Packing unit dimensions
mm
490 x 420 x 75
825 x 500 x 75
840 x 500 x 95
Overview of the Kathrein antenna masts
Type
ZSD 48
ZSF 47
ZSF 48
ZSH 47
ZSH 48
ZSH 59
ZSH 62
2)
Order Number
218380
218385
218381
218386
218394
218382
218383
Lenght L
m
2 x 2 = 4
2 x 2.5 = 5
2 x 3 = 6
Diameter D
1
/D
2
mm
40/48
48/60
Cable entry points
3
-
3
-
3
5
5
Quality category (steel)
St 52
St 37
St 52
St 37
St 52
St 52
St 52
Wall thickness in clamping range
mm
2.5
2
2.5
2
2.5
2.5
4.5
Allowable bending moment
1)
,
Effectice length at 800 N/m
2
5,0 m
4,0 m
3,0 m
-
-
1170
-
500
540
-
1,040
1,080
320
430
-
850
960
-
1,150
1,280
-
1,950
(1,150)
2,120
(1,280)
-
Allowable bending moment
1)
,
Effectice length at 800 N/m
2
5,0 m
4,0 m
3,0 m
-
-
1110
-
390
480
-
920
1000
160
300
-
700
840
-
900
1,080
-
1,700 (900)
1,960 (1080)
-
Packing unit/weight
P./kg
1/11.4
1/11.3
1/14.2
1/13.1
1/17.8
1/20.5
1/37.5
1) The maximum allowable moment on the clamping point applies for the appropriate effectice length. The wind load absorption of the tube
has already been allowed for. The bold values apply for an ordinary wind load (q = 800 N/m
2
). In case of increased wind load
(q = 1,100 N/m
2
), the reduced values apply.
According to EN 50083-1, the mast clamping length must be at least 1/6 of the mast length.
2) The technical data underlie the computation base according to DIN 4131.
If the sum of the antenna wind load moments exceeds the values put in parentheses (
≙
1,650 Nm at clamping point), a structural analysis is
required, according to EN 50083, part 1.
www.kathrein.de
KATHREIN-Werke KG
Anton-Kathrein-Straße 1-3
P.O. Box 10 04 44
83004 Rosenheim
Germany
Phone +49(0)8031 1840
Fax +49(0)8031 184306
936
.2
595/
B
/11
04/
4.
4
e/Z
W
T
S
ub
ject
to
te
ch
n
ical
ch
an
ge
s.
Transmitter
Transmitter
Rotation
90°
counter-
clockwise
Î
Cable outlet pointing slantwise
down
Writing legible