Safety Instructions

The UAS 582 feed system may only be mounted to the listed Kathrein parabolic antennas. The feed 

system is subject to the same safety and danger warnings as listed in the instructions for using of
fset parabolic antennas. Please follow these instructions at all times, as otherwise you or other 

people may be exposed to danger (electric shock through overhead lines, risk of falling down, falling 

parts, thunderstorm etc.).

Mounting and Connection of the feed system

Fixing the feed system (Fig. 1)

1.  Position the feed system as desired on the multifeed 

plate at the end of the bracket (see antenna instruc-

tions)

2.  Fasten the feed system on the front part using the 

Allen wrench (torque: 4.5 Nm).

All fastening and tightening can be effected 

with the supplied Allen wrench (SW4).

Hier ansetzen

M

A

 = 4,5 Nm

Setting the polarisation (Fig. 2)

See the value in the table Tab. 1, S. 5 for the polarisa-

tion setting.
If the value differs from the pre-set 0°, proceed as follows: 
1.  Loosen both Allen screws (S).
2.  Turn the feed system to set the reference mark to the 

value given in the polarisation pre-setting table.

3.  Tighten the Allen screws (S) evenly, alternating 

between both. 

Torque: max. 4.5 Nm

Polarisation 0°

Polari15°

Polarisation -15°

Allen screw (S)

Fig. 1:  Fixing the feed system

Fig. 2:  Setting the polarisation

Summary of Contents for UAS 582

Page 1: ...nergy saving only max 1 2 W power consumption The feed system complies with ASTRA specifications for universal Wideband feed systems Power supply via coax cable Multifeed suitable due to compact design Full protection of LNB and cable connections in a ventilated housing protection category IP 54 UAS 582 2 x F type plug Allen wrench Azimut elevations table Instructions for use Transport and Storage...

Page 2: ...n the multifeed plate at the end of the bracket see antenna instruc tions 2 Fasten the feed system on the front part using the Allen wrench torque 4 5 Nm All fastening and tightening can be effected with the supplied Allen wrench SW4 Hier ansetzen MA 4 5 Nm Setting the polarisation Fig 2 See the value in the table Tab 1 S 5 for the polarisa tion setting If the value differs from the pre set 0 proc...

Page 3: ... cable types LCD 90 LCD 111A LCD 115A oder LCD 120A montieren and connect to the LNB see Fig 4 3 When connecting the matrix and the LNB make sure the correct output is assigned mark cables if neces sary 4 It is important to ensure that the bending radius of the corresponding cable is not undershot 5 Lead the connected cable forwards and insert side ways into the cable fastening see close up in Fig...

Page 4: ...mization As the antenna lobe Fig 7 in the maximum range is only slightly curved an excellent signal strength quality can be expected when it is aligned to this range However it may also be that the antenna at the left or right is only just aligned to this excellent reception range As soon as the antenna stanchion experiences any vibration the supposed excellent signal strength quality can drop off...

Page 5: ...7 20 23 36 Liechtenstein 26 10 5 2 6 3 0 2 10 13 16 31 Luxemburg 26 11 7 4 8 6 3 1 6 9 12 26 Monaco 31 13 9 5 9 6 3 0 9 13 16 32 Niederlande 25 10 6 4 8 6 4 1 5 8 10 24 Norwegen 11 2 4 6 1 2 4 5 9 10 12 19 Österreich 24 6 1 2 2 0 3 6 13 16 18 32 Polen 17 0 4 7 2 5 7 9 15 18 20 31 Portugal 43 28 24 22 26 23 20 17 8 3 0 24 Rumänien 16 4 10 13 9 11 14 17 23 26 28 38 Schweden 12 1 3 6 1 2 4 5 9 11 13 ...

Page 6: ...2 ESU 51 2 ESU 53 8 ESU 53 Modus B 12 UB Wideband SAT 1 2 UAS 582 with Single Cable Multi Switch EXD 1524 UAS 582 with Single Cable Multi Switch EXD 1532 KAZ 11 12 2x UAS 582 KAZ 12 21810002 A KAZ 11 507205 A 2 ESU 56 2 ESU 56 2 ESU 53 8 ESU 53 EXD 1532 2 ESU 51 4 ESU 53 8 ESU 53 Modus A 2 x 16 UB Wideband SAT 1 2 DC Terr V high H high V low H low 20510104 18V 500m A max 18V 2 ESU 51 2 ESU 56 ...

Page 7: ...5 x 44 Packing dimensions mm 295 x 185 x 65 Approx weight kg 0 8 KAZ 11 12 UAS 582 POW ER STR EAM 24 V H ONE CABLE WIDEBAND EXIP 4124 SAT IP Server BN 20510136 250 2300 MHz 14 18 V 2x 1 A max 5V 500mA USB 2 0 ETHERNET RESET ON OFF 12V 4A KATHREIN Werke KG Anton Kathrein Straße 1 3 83022 Rosenheim Germany KAZ 12 21810002 A KAZ 11 507205 A UAS 582 with SAT IP Server EXIP 4124 Disposal Electronic equ...

Page 8: ...www kathrein com sat kathrein de 9360000285 a STD 1218 GB Subject to change KATHREIN SE Anton Kathrein Str 1 3 83022 Rosenheim Germany Telefon 49 8031 184 0 Fax 49 8031 184 52360 ...

Reviews: