background image

9 / 16

4.  Save the protective caps to protect the connectors of the cables/devices when 

removing or remodelling.

5.  The minimum allowed bend radius for the fi bre optic cable is 15 mm during the instal-

lation and 10 mm during use. A smaller radius signifi cantly increases the attenuation 
and may cause damage to the fi bre optic cable. Fibre optic cables must always be 
handled carefully - especially during installation.

Cleaning optical connections:

If an optical connector (male) has been repeatedly inserted and unplugged or if failure 
occurs, it may be necessary to clean the optical connector pins or sockets.
For cleaning purposes please use the optical cleaning set ORS 1 or the optical cleaning 
tool ORW 1.

Input level optical transmitter OSC 100 micro

To ensure that the signals are transmitted through the fi bre optic cables, the RF signals 
must meet the following requirements:

TV (DTT/CATV) 

 DVB-T, Cable TV

To ensure that the digital television signals are transmitted and received, the digital signals 
to the transmitter should be set to the same high level, especially when multiple digital 
channels are transmitted.
As a guide, the input signals should meet the following requirements:
1.  With QAM64, a maximum of 40 TV channels can be transmitted, with QAM256, a 

maximum of 20 TV channels. 

With limitations on signal quality, up to 25 QAM256 

TV channels can be transmitted. Wherever possible, a TV channel grid in the lower 

frequency range should be preferred.

2.  Total input power: -19 dBm (90 dBμV)
3.  Depending on the number of digital TV channels, the following levels must be met at 

the optical transmitter’s (OSC 100 micro) TV input:
All levels are stated per digital TV channel
• 40 TV channels with a maximum of 74 dBμV
• 20 TV channels with a maximum of 77 dBμV
• 16 TV channels with a maximum of 78 dBμV
• 10 TV channels with a maximum of 80 dBμV
• 8 TV channels with a maximum of 81 dBμV

The minimum input level (per digital channel) should be at least 74 dBμV.
If the quality of the TV input signal is not optimal or when the digital TV channels cannot 
be equally levelled, the system should be adapted so that the optical attenuation of less 
than 21 dB is reached to ensure correct signal reception at the outlet (especially when 
many digital channels are transmitted).

Summary of Contents for OSC 100 micro

Page 1: ...ransmitter OSC 100 micro and the optical receiver OEC 40 micro and OEC 44 micro can be used to distribute satellite and digital terrestrial signals FM DAB digital TV through a single mode fibre optic...

Page 2: ...e with the local security standards and regulations The unit complies to protection class II and thus need not be connected to the protective earthing of the mains supply The safety regulations set ou...

Page 3: ...high Terr opt on Fibre H low V low H high V high Terr 14V max 200mA Terr H high Test 205500005 LASER CLASS 1M Risk of material damage to the device If the inner cable conductor diameter is more than 1...

Page 4: ...ptical distribution network make sure that the lasers of the connected transmitter have been switched off by disconnecting the mains plug Do not open the unit or tamper with it Under no circumstances...

Page 5: ...st output SAT F type connector for the SAT test signal HH polarity RF level 60 dB V per transponder 5 Test output TV F type connector for the digital terrestrial signal 87 5 862 MHz RF level 74 dB V t...

Page 6: ...bonding as per EN 60728 11 3 Optical input CLIK input Used for optical bre connection Outputs F type connectors 4 OEC 44 micro Terrestrial Sat Four combined outputs for FM DAB digital TV 87 5 862 MHz...

Page 7: ...em Please use the Kathrein CLIKulator to plan and adjust your optical distribution network http clikulator com kathrein If directly connected without splitters or taps attenuators must be used between...

Page 8: ...ssive OAC and OVC units as well as the suitable optical connectors ODC xxx Unused coaxial outputs must be terminated with an optical termination OTC 1 without fail Otherwise the proper functioning of...

Page 9: ...be set to the same high level especially when multiple digital channels are transmitted As a guide the input signals should meet the following requirements 1 With QAM64 a maximum of 40 TV channels can...

Page 10: ...onnectors must be terminated with EMK 03 with the exception of the 4 SAT inputs of the OSC 100 micro which due to DC voltage must be terminated with EMK 05 All unused optical connectors of the optical...

Page 11: ...for each channel is 71 dB V at the output of the receiver at 15 dB of optical attenuation and if 120 transponders are used The typical SAT signal output level on the OEC 40 micro output is Transponde...

Page 12: ...input level dB V 90 Test outputs Bandwidth MHz 87 5 862 1100 2150 HH polarity Connector type F type socket Output return loss dB 10 RF output level dB V 59 digital TV and Sat H H Optical output Conne...

Page 13: ...ted voltage range V Hz 220 240 50 60 Operational voltage V mA 14 380 18 330 all outputs Power consumption W 3 3 5 Operating temperature C 5 to 45 LED information Power indicator Green LED Dimensions W...

Page 14: ...GC of the OSC 100 micro optical transmitters ensures a constant optical output level independent of the number of digital terrestrial TV channels or the number of transmitted SAT transponders The sign...

Page 15: ...irektanschluss am optischen Empf nger Koaxialkabel Glasfaserkabel Optischer Empf nger mit schaltbaren Ausg ngen OEC 40 micro 20550 0002 Fibre V low H low V high H high Terr Powe r OEC 44 micro 20550 0...

Page 16: ...ww kathrein ds com support kathrein ds com 936500060 b STM 0221 GB Subject to change KATHREIN Digital Systems GmbH Anton Kathrein Str 1 3 83022 Rosenheim Germany Phone 49 731 270 909 70 For your notes...