www.kathrein-ds.com
9360000407/c/PM/0720/GB | Subject to change.
KATHREIN Digital Systems GmbH
|
Anton-Kathrein-Str.1 – 3
|
83022 Rosenheim
|
Germany
|
Phone +49 731 270 909 70
SAVE DATALOGGER
Display the
SAVE DATALOGGER
menu
+
1. Press
ON/OFF HOME
, then
MEMORY
.
➯
The
SAVE DATALOGGER
appears.
SAVE DATALOGGER
2. Select
SAVE DATALOGGER
.
ENTER
3. Press the navigation wheel.
➯
The setting menu appears.
Set the
SAVE DATALOGGER
function
Data File:
1. Select
Data File
and press the navigation wheel.
LOG. 1
2. Select the data file (
LOG. 1
,
LOG. 2
etc.) with the navigation wheel and
press the navigation wheel.
Point:
3. Select
Point
and press the navigation wheel.
POINT 1
4. Select the point (
POINT 1
,
POINT 2
etc.) with the navigation wheel and
press the navigation wheel.
Start the
SAVE DATALOGGER
function
START OVERWRITE?
START SAVE?
►
Select
START OVERWRITE?/START SAVE?
and press the navigation
wheel.
➯
The scan starts (takes a few minutes). The result is then saved
automatically.
DC at TV HF input
1. Press to display the TV signal.
DC@RF
2. Select
DC@RF
and press the navigation wheel.
DC@RF
18V
3. Select a value (
5V
/
12V
/
18V
/
24V
) and press the navigation wheel.
Notice
►
Carry the device case by means of the handle
①
(example in Fig. 1) or the shoulder strap (no picture).
►
Insert the shoulder strap’s hooks as shown in Fig. 1.
This helps prevent inadvertent loosening of the
hooks.
►
To transport the device, connect the shoulder strap’s
snap hooks to D-rings
①
+
②
or
③
+
④,
and to take
measurements, to D-rings
①
+
④
or
②
+
③.
3
4
A
1
2
Fig. 1:
Correct snap hook connection