FM measurement
43
Bearing for Individual Reception Frequencies
The „LEVEL
♫
“ function allows the antenna alignment to maximum
received signal via bearing. The level tendency can be bargraph-
displayed. The measurement range can be adjusted to three different
sensitivity levels.
The level can be monitored with an acoustic signal, the pitch of which is
proportional to the received-signal level. The volume of the acoustic
signal can be adjusted with the volume regulator.
Bearing Menu
[2ndF]
[LEVEL
♫
]
Changing over to bearing mode
[-] [+]
Change-over of the measurement range of the bar
graph. The measurement range is automatically
preselected.
Level range 1:
high input levels
Level range 2:
medium input levels
Level range 3:
low input levels
[2ndF]
[2ndF]
Exit
LC display:
•
Level range 2: medium input level
•
Mode: TV
•
Bargraph display
Example
Calling up „
LEVEL
♫
“ function:
Press
[2ndF] [LEVEL
♫
].
Move the antenna until the maximum amplitude of the bargraph display is
reached.
If necessary, diminish or elevate the sensitivity by pressing either
[-]
or
[+]
Repeat this procedure until the maximum level is reached.
Closing LEVEL mode:
Press
[2ndF]
twice.
À
LEV-RANGE:2 FM
>
■■■■
✐