NOTICE

Multi-switches without Kathrein Power Saving do not give signalling to the 

end multi-switch. For permanent powering of the LNB, the rotary switch 

must be turned to the left side.

NOTICE

Changes in the confi guration during operation can lead to undesirable 

confi gurations and malfunction.

Do not alter the confi guration during operation.

Multi-Switch Modes

There are two diff erent modes that you can 

set:

A

: 8 (

EXR 

): 8 user bands per output are 

available In this mode, the multi-switch 

uses the same frequencies as the 

EXR

single-cable multi-switch series (fi rst 

generation).

B

: 12 (

EXE

): 12 user bands per output are 

available. In this mode, the multi-switch 

uses the same frequencies as the Kath-

rein EXE single-cable multi-switch series 

(second generation).

Satellite positions

:

1...4 SAT

: The possible positions are presented by means of numbers on the multi-

switch:

When operated with Universal LNB(s), 2 satellite positions are possible. 

When operated with wideband LNB(s), up to 4 satellite positions are possible.

With 

one

 EXD 1524/2524 it is possible:

to receive one satellite in the universal mode.

to receive two satellites in the wideband mode.

With 

two

 EXD 1524/2524 it is possible:

to receive two satellites in the universal mode,

to receive four satellites in the wideband mode.

To do so, it is necessary to connect the outputs of the two EXD 1524/2542 to a splitter 

(EBC 110).

Summary of Contents for EXD 1524

Page 1: ...am menschalten der Ausgänge mit dem Verteiler EBC 110 Einkabelbefehlssatz EN 50494 und der neue erweiterte Befehlssatz EN 50607 SCD 2 werden unterstützt Zukunftstauglich durch Wideband Technology breitbandige Eingänge mit Wideband LNBs sind bis zu vier Satellitenpositionen möglich Die integrierte AGC Automatic Gain Control sorgt für einen konstanten Ausgangspegel der Sat ZF Signale und für mehr Re...

Page 2: ...rät in der Originalverpackung transportieren und trocken lagern Sicherstellen dass kein Kondenswasser gebildet wird Stromführendes Gerät NCF 18 Sicherheitshinweise WARNUNG Lebensgefahr durch elektrische Spannung Nicht öffnen oder am Netzteil manipulieren Bei Arbeiten an der Anlage immer das Netzteil aus der Steckdose ziehen Das Netzteil ist nur für die Wandmontage vorgesehen Alle anderen Einbaulag...

Page 3: ...ei Betonuntergrund und Mauerwerk 2 dafür geeig nete Dübel und zugehörige Schrauben mit Halbrund oder Zylinderkopf Gewindeaußendurchmesser 4 5 5 mm Kopfdurchmesser 7 mm und einer Schraubenlänge 30 mm Verwenden Sie bei anderen Wandarten die jeweils dafür geeigneten Schrauben oder Schrauben Dübel Systeme die eine gleiche oder bessere Befestigung ermöglichen Verbindungsstecker HF Stecker 75 Ω Serie F ...

Page 4: ...en höheren Frequenzen zuzuordnen Per Definition ist das System so ausgelegt dass Einkabelgeräte mit 14 V DC versorgt werden Zum Übertragen der DiSEqC Steuersignale wird die Versorgung kurz zeitig auf 18 V DC geschaltet Dauerhaft angelegte 18 V würden das System blockieren Aus diesem Grund empfiehlt sich die Verwendung von Steckdosen der ESU Serie die mit einer elektronischen Abschaltung versehen s...

Page 5: ... wird zusätzlich am Eingang HH eine LNB Speisespannung ausgegeben Wenn nur eine Satellitenposition benutzt wird ist es notwendig die nicht benützten Eingänge mit DC entkoppelten Widerständen z B EMK 05 abzuschließen Drehschalter Der Drehschalter ist das zentrale Element des Multischalters mit welchem die Betriebsart und Funktionalität eingestellt werden Kathrein Power Saving Der Drehschalter ist i...

Page 6: ...wie die EXR Einkabel multischalterserie 1 Generation B 12 EXE an beiden Ausgängen stehen je 12 Userbänder zur Verfügung Der Multischalter nutzt in diesem Modus die gleichen Frequenzen wie die Kathrein EXE Einkabelmultischalterserie 2 Gene ration Satellitenpositionen 1 4 SAT Auf dem Multischalter werden die möglichen Positionen durch Zahlen darge stellt Bei Betrieb mit Universal LNB s sind bis zu 2...

Page 7: ...berer Anschluss UB 1 974 MHz 1284 MHz UB 2 1076 MHz 1400 MHz UB 3 1178 MHz 1516 MHz UB 4 1280 MHz 1632 MHz UB 5 1382 MHz 1748 MHz UB 6 1484 MHz 1864 MHz UB 7 1586 MHz 1980 MHz UB 8 1688 MHz 2096 MHz UB 9 1790 MHz UB 10 1892 MHz UB 11 1994 MHz UB 12 2096 MHz Ab UB 9 wird SCD 2 benötigt Hiermit erklärt die KATHREIN Digital Systems GmbH dass die Geräte EXD 1524 BN 20510137 EXD 2524 BN 20510138 der Ri...

Page 8: ...8 10 Anlagenbeispiele symbolische Darstellung ...

Page 9: ...meranschluss V 19 19 Max zul Fernspeisestrom Einganghoriz low mA 500 2x 250 bei Wideband Max zul Fernspeisestrom pro Stamm mA 1000 Max VersorgungsspannungamDC Anschluss V 18 6 18 6 Schutzart IP 30 IP 30 Zulässige Umgebungstemperatur C 20 bis 55 20 bis 55 Anschlüsse F Connectoren F Connectoren Abmessungen mm 102 8 x 148 x 44 111 5 x 148 x 44 Verpackungseinheit Gewicht St kg 1 10 0 51 1 10 0 4 Netzt...

Page 10: ...che Zuordnung Sicherstellen dass UB und Frequenz überein stimmen Achtung SCR Adresse ist um 1 kleiner als UB Nr Keine Spannung am LNB Netzteil NCF 18 an EXD 1524 einstecken Verbindung Receiver LNB auf Kurzschluss überprüfen DC Block EMU 12 BN 273281 an den Kaskadeneingang anschließen damit Stamm VL durch LNB nicht zu stark belastet wird Nur bei UB 8 Schlechtes oder kein Signal Receiver unter stütz...

Page 11: ...uts with the splitter EBC 110 EN 50494 single cable set of commands and the new extended EN 50607 SCD 2 set of commands are supported Future proof due to Wideband tech nology broadband inputs up to four satellite positions possible due to wideband LNBs The integrated AGC Automatic Gain Control ensures that the Sat IF signals have a constant output voltage and more reserve in the distribution EXD 1...

Page 12: ...nd store the device in its original packaging Make sure there is no water condensation build up Current carrying device NCF 18 Safety Instructions WARNING Danger to life due to electric shock Do not open the unit or tamper with it When working on the system always unplug the power supply unit from the wall socket The device is intended only for wall mounting All other installation positions are pr...

Page 13: ...s for concrete substrates and masonry 4 suitable plugs and asso ciated screws with half round or cylindrical head outer thread diameter 4 5 5 mm head diameter 9 mm and a screw length 30 mm For other types of wall use the appropriate screws or screw dowel systems which offer the same or better fastening Connector RF plug 75 Ω series F to EN 61169 24 Unused subscriber ports should be closed off with...

Page 14: ...ec tions to the higher frequencies By definition the system is designed so that single cable devices are supplied with 14 V DC The power supply is briefly switched to 18 V DC if control signals similar to DiSEqC have to be transmitted Continuous application of 18 V would block the system For this reason we recommend the use of the ESU series outlets which are equipped with an electronic switch off...

Page 15: ...ge is provided at the HH input in all posi tions marked in black If only one satellite position is used it is necessary to terminate all the inputs which are not in use with DC decoupled resistors e g EMK 05 Rotary Switch The rotary switch is the central element of the multi switch It sets the operation mode and functionality Kathrein Power Saving The rotary switch is divided into the left and the...

Page 16: ...XE 12 user bands per output are available In this mode the multi switch uses the same frequencies as the Kath rein EXE single cable multi switch series second generation Satellite positions 1 4 SAT The possible positions are presented by means of numbers on the multi switch When operated with Universal LNB s 2 satellite positions are possible When operated with wideband LNB s up to 4 satellite pos...

Page 17: ...UB 1 974 MHz 1284 MHz UB 2 1076 MHz 1400 MHz UB 3 1178 MHz 1516 MHz UB 4 1280 MHz 1632 MHz UB 5 1382 MHz 1748 MHz UB 6 1484 MHz 1864 MHz UB 7 1586 MHz 1980 MHz UB 8 1688 MHz 2096 MHz UB 9 1790 MHz UB 10 1892 MHz UB 11 1994 MHz UB 12 2096 MHz SCD 2 is necessary starting from UB 9 Hereby KATHREIN Digital Systems GmbH declares that the radio equipment types EXD 1524 order no 20510137 EXD 2524 order n...

Page 18: ...8 10 System Examples Symbolic Representation ...

Page 19: ...V 19 19 Max permissible remote feed current input horiz low mA 500 2x 250 for wideband Max remote feed current per trunk mA 1000 Max supply voltage at DC connection V 18 6 18 6 Protection class IP 30 IP 30 Permissible ambient temperature C 20 to 55 20 to 55 Connections F type connectors F type connectors Dimensions mm 102 8 x 148 x 44 111 5 x 148 x 44 Packing unit weight pc kg 1 10 0 51 1 10 0 4 P...

Page 20: ...R address is smaller than the user band number by 1 No voltage on the LNB Plug in the power supply unit NCF 18 into the EXD 1524 Make sure there is no short circuit on the receiver multi switch connection connect DC block EMU 12 order no 273281 to the cascade input to reduce the load placed on the VL trunk from the LNB Only for UB 8 Poor or no signal Receiver does not support SCD2 according to EN ...

Reviews: