Technical Data

Type | Order No.

ESO 180 H

237500004

ESO 180 HL

237500006

Suitable for satellite antenna

CAS 180

Permissible ambient temperature

°C

-40 to +80

Recommended installation temperature °C

+15 to +30

Nominal temperature (frost protection) °C

+3

Over-temperature protection (opener)

°C

+80

Operational voltage

V

230; 115 per two heating shells connected in series (+6%/-10%; 50 to 60 Hz)

Rated current approx.

A

6

12

Rated voltage

V

230

Rated power approx.

W/m

2

500

Heating power approx.

W

1400

2750

Insulation resistance

MΩ

> 20

Dielectric strength

kV

2.5

Protection class

IP 65

Working life min.

10 years

Weight approx.

kg

 4.3

Design and construction type acc. to

DIN VDE 0100, DIN EN 60519-1 VDE 0721-1, DIN EN 50173-4 VDE 0800-173-4

Corresponds to standards

EN 61000-6-1, EN 61000-6-3, EN 1010-1, EN 60519-1, EN 60519-2

Excess temperature cut-out

Design

Opener

Position

Antenna back panel in the middle of the heating area in the top third

Type of connection

Connected in series to the heating element in the heating mats

Connection cables

Length

m

3.5

Diameter

mm

2

3 x 1

Sensor cable

Length approx.

m

4

Diameter

mm

2

2 x 0.22

Electronic equipment

Electronic equipment is not domestic waste – in accordance with directive 2012/19/EC OF THE EUROPEAN PARLIAMENT 

AND THE COUNCIL dated 04th July 2012 concerning used electrical and electronic appliances, it must be disposed of 

properly. At the end of its service life, take this unit for disposal at a designated public collection point.

Disposal

Repair and Replacement

autronic electronic-service GmbH

Hauptstraße 2a

35792 Löhneberg-Obershausen

Germany

Phone:  +49 6477 612 310 1

Fax: 

+49 6477 612 302 0

Email: [email protected]

Maintenance

Check the correct attachment and seating of the heating mats on the refl ector at regular intervals.