Risk of damage to the unit!

Test the heating for contact resistance and insulation resistance (Ri) before connecting the cables in the control 

device. For target values, see the instructions for use of the refl ector heating.

These tests should be repeated after replacement of a defective heating tray.

1.  Run the connection cables of the heating tray along the antenna carrier to the ESO 005 control device.
2.  Use cable ties to attach the connection cables.
3.  Run the cables from the bottom through the screw connection into the control device.
4.  Run the mains cable from the bottom through the screw connection into the control device.
5.  If you use the ESO 005 temperature control, connect the cables as shown in Fig. 1, if you use the heating without the ESO 005, 

connect the cables as shown in Fig. 2.

1

2

3

4

5

6

8

7

9

10

11

12

PT 100

PE       N     |opt.|

L      L       N       PE

Heizung

Heater

Chauffage

Netz

Mains

Reseau

C

Fig. 1: ESO 005 temperature control terminal assignment

bl: 0 V

bn: 230 V

gn/gb: PE

Power cable

Cable fr

om the 

heating tr

ay

Fig. 2: Terminal assignment when using the heating without the ESO 005