Connecting the Cables
WARNING
Risk of severe injuries or material damage to the device!
►
Make sure that this work is carried out only by qualified specialist personnel.
1. Run the connection cables of the heating trays along the antenna carrier to the control device.
2. Use cable ties to attach the connection cables.
3. Run the cables from the bottom through the screw connection into the control device.
4. Run the mains cable from the bottom through the corresponding screw connection into the control device.
5. Test the heating for contact resistance and insulation resistance (R) before connecting the cables in the control
cabinet.
Heating tray
Contact resistance ±5%
Target
value
70.1 – 77.5 Ω
Actual
value
Insulation resistance
Target
value
> 999 MΩ
Actual
value
NOTICE
These tests should be repeated after replacement of a defective heating tray.
When using an outside temperature control, the corresponding cabling instructions can be found in the installa-
tion manual of that control device, e.g. ESO 005.
Maintenance
►
Check the correct attachment and seating of the heater mat on the reflector at regular intervals.
Repair and Replacement
Rep and More GmbH
Hauptstrasse 2a
35792 Löhnberg-Oberhausen, Germany
Phone: +49 6477 6123-101
Fax: +49 6477 6123-020
Email: