![Kathrein 2220000009 User Manual Download Page 9](http://html.mh-extra.com/html/kathrein/2220000009/2220000009_user-manual_657825009.webp)
9
Sketch:
•
This sketch only serves as an example. The window/door sensor can also
be installed at other positions.
•
We recommend installing the magnet on the door or window side and the
sensor on the frame.
•
Pay attention to the marking (2) when installing the sensor. The magnet
(13) must be installed close to this marking (maximum distance 20–30 mm)
to close the sensor circuit. The status (open or closed) can be monitored
in the sensor list of the web interface of the alarm centre.
Note:
•
The window/door sensor can also be installed on double casement
windows. The distance between sensor and magnet must not exceed 20–
30 mm.
•
If the sensor is installed at the bottom of a window, it is possible to tilt the
window without triggering an alarm (maximum distance between sensor
and magnet 20–30 mm). We do not recommend this type of installation, as
tilted windows represent a security risk.
•
If the window/door contact is installed on metal/steel doors, it should be
insulated from the mounting surface by means of a rubber pad. Failure to
do so may result in malfunctions.
•
Do not bypass the jumper (3) in the housing to keep the supervisor
test/battery test of the sensor activated.