KATANA S610M Inverter Specialized for Elevator Manual
6.4 Speed Parameters (Group F03)
Function Code
Parameter Name
Setting Range
Factory Default Value
F03.00
Multi-speed 0
0
~
F0.04
0.000
F03.01
Multi-speed 1
0
~
F0.04
0.000
F03.02
Multi-speed 2
0
~
F0.04
0.000
F03.03
Multi-speed 3
0
~
F0.04
0.000
F03.04
Multi-speed 4
0
~
F0.04
0.000
F03.05
Multi-speed 5
0
~
F0.04
0.000
F03.06
Multi-speed 6
0
~
F0.04
0.000
F03.07
Multi-speed 7
0
~
F0.04
0.000
F03.00
~
F03.07 defines the multi-section operation speed, which is used in multi-speed operation mode.
Pleases refer to terminal functions of multi-speed operation “3”
、
“4”
、
“5” in F07.00
~
F07.08.
F03.08
Inspection speed
0.000~0.630 m/s
0.2
This parameter defines the elevator operation speed under inspection operation (Terminal mode available).
F03.09
Emergency speed
0.020~0.150 m/s
0.1
This parameter defines the elevator operation speed under emergency operation (Speed mode and floor distance
mode are available).
F03.10
Speed detection of up forced
deceleration
0
~
100.0%
(
F00.04
)
97.0%
This parameter defines the speed detection value when up forced deceleration switch is on.
When up forced deceleration switch is on, and the operation speed exceeds the set value, the system will
reduce the elevator speed to crawling speed (F03.16) by F05.13 (deceleration under abnormal condition).
Reasonable setting of this parameter can prevent the elevator from hitting the top when going up
.
F03.11
Speed detection of down forced
deceleration
0
~
100.0%
(
F00.04
)
97.0%
This parameter defines the speed detection value when down forced deceleration switch is on.
When down forced deceleration switch is on, and the operation speed exceeds the set value, the system will
reduce the elevator speed to crawling speed (F03.16) by F05.13 (deceleration under abnormal condition).
Reasonable setting of this parameter can prevent the elevator from hitting the bottom when going down
.
F03.12
Overspeed setting
80.0%
~
130.0%
(
F00.04
)
120.0%
F03.13
Detection time of overspeed
0
:
Prohibited
0.01~2.00s
:
Detection time
0.30
When the elevator is running at a speed faster than the set value of F03.12 for a time longer than the set value